ManageEngine Logo

OpStor

Multi-Vendor Storage Management

OpStor is a heterogeneous storage infrastructure monitoring solution that helps enterprises to monitor their storage resources.
  • Multi-vendor storage infrastructure management
  • Pro-active Fault and Performance monitoring
  • Visualize SAN availability and health
  • Detect problems with utilization and availability of storage devices.
 
Success Stories
"OpStor lets us monitor our entire storage environment, Servers, HBA's, Switches, and the SAN." - Bryan Dearlove, - Information Guelph General Hospital » More Success Stories
 

Monitoring EMC CLARiiON RAID Networked Storage Systems

OpStor provides monitoring and management of EMC CLARiiON RAID Networked Storage Systems

  • CX series like
    • CX3-20
    • CX3-40
    • CX3-80
    • CX4
    • CX300
    • CX400
    • CX500
    • CX600
    • CX700
    • CX800
  • FC Series like FC4700
  • AX 4

Features supported
Inventory Details Logical Details Monitors Report Details
  • Storage Processors
  • SP Ports
  • Disk Drives
  • LUNs
  • Raid Grouos
  • Host-Port Mappings
  • SP Status
  • SP Port status
  • Disk Drive status
  • LUN status
  • Raid Group status
  • Capacity Summary
  • Availability for SP / SP Ports
  • SP statistics
  • LUN statistics
  • Disk statistics
  • Interconnect details

Prerequisites for monitoring EMC CLARiiON

OpStor uses command line utility (NaviCLI.exe/NaviSecCLI.exe) available as part of NaviSphere suite of EMC CLARiiON RAID

  • NaviCLI/NaviSecCLI should be installed in the server in which OpStor is installed.
  • Include the directory containing NaviCLI.exe/NaviSecCLI.exe in the PATH environment variable. (This is normally C:\Program Files\EMC\Navisphere CLI\ )
  • Ensure that OpStor is restarted (shutdown & started) after including NaviCLI/NaviSecCLI in the path. This is required for the latest path changes to take effect for OpStor
  • Now open a command prompt to execute the navicli command to check for the proper response from EMC CLARiiON RAID
    • Command : navicli -h <array name> getall (for systems with NaviCLI installed)
    • Command : naviseccli -h <array name> -scope 0 -user <storage system username> -password <storage system password> getall (for systems with NaviSecCLI installed)
  • Ensure that, OpStor installed host and the Storage system has a Fibre Channel Connectivity.
emc raid

How to enable Performance monitoring on EMC CLARiiON

For Performance monitoring, please ensure that setStats flag is enabled. You can enable this using following command in the array

Command : navicli -h <array-ip> setstats -on


Steps to add EMC CLARiiON in OpStor
  • In the OpStor client go to Admin Tab -->Manage Storage Devices
  • Provide IP Address of EMC Clariion Array
  • Choose the Device Type as 'RAID'
  • Choose the Vendor as 'EMC'
  • Choose the Model as 'Clariion'
  • If you are adding CX4/AX4, then provide the Username, Password and Community string.
  • Change the Timeout if needed.
  • Click on Add Device
  • Repeat the above procedure to add the second array IP in case of dual Storage Processors.

Note : If the Ping facility is disabled for the device, then please uncheck 'Ping the given IP' field.
Note : In case of non discovery of the device, please follow the troubleshooting tips displayed in the webclient and try re-adding the device. 

Storage Management Software