• Active Directory
  • Application
  • Desktop & Mobile
  • Help Desk
  • Network
  • Server
  • IT Security
  • MSP
  • On-Demand
 
 
Device Management, made easy
Manage control and secure your workstations, mobile
devices and tablets
 
 
Help Desk for Everyone
IT Help Desk Software and Customer Support Software
 
 
Protect Your IT. Save Your Business
Build a secure fortress with our security management solutions
 
 
MSP
Manage services faster, with multi-tenanted, ITIL-ready, and unified RMM solutions
 
 
On-Demand Solutions
IT Help Desk, Active Directory, and Operations Management from the Cloud
 

Monitoring of Hitachi TagmaStore

Monitoring of Hitachi TagmaStore Series Storage Systems in OpStor

OpStor provides monitoring and management of Hitachi TagmaStore Series storage systems

Models Supported

  • AMS 200
  • AMS 1000
  • AMS 1500
  • AMS 2100
  • AMS 2300
  • AMS 2500
  • WMS 100
  • NSC 55
  • USP
  • USP-V (or) HP XP24000
  • VSP
  • HUS 130,150

For monitoring the TagmaStore arrays, OpStor uses two methods.

  1. Monitoring via SNMP
  2. Monitoring via SMI-S Provider

Monitoring via SNMP :

Features supported (when monitored through SNMP)

Inventory Details Logical Details Monitors Report Details
  • Raid Controllers
  • Raid Controller Ports
  • LUNs
  • LUN Host Mappings
  • InterConnects Info
  • Raid Controller Status
  • Raid Controller Port Status
  • Availability Reports
  • LUN Performance

Prerequisites for monitoring Hitachi TagamaStore Arrays through SNMP

  • Ensure that SNMP agent is running in the Hitachi TagmaStore device
  • Register OpStor server IP address as trap destination

Steps to add Hitachi TagmaStore series in OpStor (through SNMP)

  • Navigate to Admin Tab --> Manage Storage Devices link in OpStor client
  • Provide IP Address of Hitachi Raid
  • Choose the Device Type as 'RAID'
  • Choose the Vendor as 'Hitachi'
  • Choose the Model as Thunder'
  • Provide SNMP Port and Community string (default is 161 and public)
  • If needed, change the Timeout value (default is 5 seconds)
  • Click on Add Device

Note : If the Ping facility is disabled for the device, then please uncheck 'Ping the given IP' field.
Note : In case of non discovery of the device, please follow the troubleshooting tips displayed in the webclient and try re-adding the device.
Note : Hitachi Device Manager, version 7.0.1 or later is required to support the discovery and monitoring of Hitachi VSP Storage.

Monitoring via SMI-S Provider

Features supported (when monitored through SMI-S)

Inventory Details Logical Details Monitors Report Details
  • Array Controllers
  • Array Controller Ports
  • Disk Drives
  • Components
  • Array Groups
  • Storage Pools
  • Storage Volumes
  • LDEV Info
  • Array Status
  • Controller Status
  • Controller Port Status
  • Drive status
  • Storage Pools status
  • Storage Volumes status
  • LDEV Status
  • Components Status
  • Capacity Summary

Prerequisites for monitoring Hitachi TagmaStore Arrays through SMI-S

  • OpStor uses Hitachi SMI Provider to monitor the Hitachi Array
  • This Provider can be installed on any server that is reachable from the server where OpStor is installed.

Steps to add Hitachi TagmaStore series in OpStor (through SMI-S)

  • Navigate to Admin Tab --> Manage Storage Devices link in OpStor client
  • Provide IP Address of server where SMI-S Provider is running
  • Choose the Device Type as 'RAID'
  • Choose the Vendor as 'Hitachi'
  • Choose the Model as 'SMI-S'
  • In Username field enter the SMI-S Provider username
  • In the Password field enter the SMI-S Provider password
  • Provide the Port number at which the CIM Agent is running(5989 or 5988)
  • Choose whether the SSL should be Enabled(https) or Disabled(http)
  • Provide the name space (by default root/hitachi/dm55). This namespace has to be modified depending on the version of HiCommand Device Manager. For example, if the version of HiCommand Device Manager installed is 5.8, then you need to change "dm55" to "dm58". If you are adding Hitachi VSP Storage then you need to specify namespace as /root/smis/smis15 (or) /root/smis/current
  • Change the Timeout, if needed
  • Click on Add Device.

Note : If the Ping facility is disabled for the device, then please uncheck 'Ping the given IP' field.
Note : In case of non discovery of the device, please follow the troubleshooting tips displayed in the webclient and try re-adding the device.
Note : Hitachi Device Manager, version 7.0.1 or later is required to support the discovery and monitoring of Hitachi VSP Storage.

Multi-Vendor Storage Management trusted by

>