Analytics-Plus Help

Installation Guide - ManageEngine Analytics Plus

 

Introduction

 

This ManageEngine Analytics Plus Installation Guide will help you complete the installation process of ManageEngine Analytics Plus successfully and start creating reports and dashboards on your data.

 

 

System Requirements

The minimum system requirements for effectively running ManageEngine Analytics Plus are given below.

 

Prerequisites

 

  • Both, the Professional and Presonal editions can be installed in a VMWare environment.

  • Anti-virus scan needs to be excluded for the folder where ManageEngine Analytics Plus is installed (eg. C:/ManageEngine/AnalyticsPlus)

  • The hostname of the server where ManageEngine Analytics Plus is to be installed should not contain the underscore ( _ ) symbol in it.Note that if your server hostname contains "_" (underscore), it may affect the ManageEngine Analytics Plus service startup and make certain services inaccessible on TCP/IP networks.For example, use the server hostname: https://manageengine-analyticsplus:8443 instead of https://manageengine_analyticsplus:8443

NOTE:

  • Installing PGSQL using root user in Linux environment is not supported currently.

  • Please make sure that the installation directory or its parent directories do not have any space character in its name.

 

Professional Edition Prerequisites: 

 

Specification

Evaluation

Production

OS

Ubuntu 12 Precise Pangolin,Quantal Quetzal

Ubuntu 14 Trusty Tahr

Ubuntu 16 Xenial Xerus

Ubuntu 12 Precise Pangolin,Quantal Quetzal

Ubuntu 14 Trusty Tahr

Ubuntu 16 Xenial Xerus

Processor

1 GHz

2 GHz, Quad core processor

Memory

4 GB

8GB

HardDisk

80 GB

250GB

Supported browsers

Firefox v40 and aboveGoogle Chrome v40 and aboveFirefox v40 and above Google Chrome v40 and above

 

Personal Edition Prerequisites:

 

Specification

Minimum requirement

OS

Ubuntu 12 Precise Pangolin,Quantal Quetzal

Ubuntu 14 Trusty Tahr

Ubuntu 16 Xenial Xerus

Processor

1 GHz

Memory

4GB

HardDisk

80GB

Supported browsers

Firefox v40 and above

Google Chrome v40 and above

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

ManageEngine Analytics Plus Editions

 

ManageEngine Analytics Plus is available in two editions namely,

  • Personal Edition - This edition of ManageEngine Analytics Plus is a Single User version that installs on desktop or laptop and is meant for individual users. This edition offers no collaboration capabilities.

  • Professional Edition - This edition of ManageEngine Analytics Plus is a Multi-User version that installs on a server grade machine and is meant for multiple users to create reports and share amongst them.

 

Edition comparison:

 

Modules / Features

Personal Edition

Professional Edition

Users

1

As per purchased license

Reports / Dashboards

Unlimited

Unlimited

Databases

5

Unlimited

Query Table Support

10

Unlimited

Generate Links

No

Yes

Rebranding

No

Yes

Sharing and Collaboration

No

Yes

Back Up options

No

Yes

Scheduled Email

No

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

Setup

 

Installation File 

 

Linux:

Download ManageEngine_AnalyticsPlus_64bit.bin (for 64 bit Linux OS) here

 

Installation procedure

 

Step 1:

 

Install ManageEngine Analytics Plus on a Linux machine by downloading ManageEngine_AnalyticsPlus_64bit.bin file.

 

Step 2:

 

To execute .bin type files, you require the execute permission. Enter the command as given below in your command prompt. #chmod a+x ManageEngine_Analytics_Plus_x_Linux.bin

 

Step 3:

 

Execute the .bin file ./ManageEngine_AnalyticsPlus_64bit.bin

 

Step 4:

 

The ManageEngine Analytics Plus Installation Wizard is displayed. Click on "Next" to proceed with the installation.

 

Step 5:

 

The License Agreement is displayed. Please read the license agreement carefully. You need to accept the license agreement to proceed with the installation.

 

Step 6:

 

Select the "I accept the terms of the License Agreement" radio option, to proceed with the installation process

 

Step 7:

 

Click on "Next" to proceed with the Installation process.

 

Step 8:

 

Select the ManageEngine Analytics Plus Edition to install.

 

  • Personal Edition - This edition of ManageEngine Analytics Plus is a Single User version that installs on desktop or laptop and is meant for individual users. This edition offers no collaboration capabilities.

  • Professional Edition - This edition of ManageEngine Analytics Plus is a Multi-User version that installs on a server grade machine and is meant for multiple users to create reports and share amongst them.

 

Step 9:

  • If you have selected Professional Edition, then the "License Info" tab in ManageEngine Analytics Plus product, displays only the 30 days of Trial Version. You need to apply for a valid license to continue using ManageEngine Analytics Plus after the trial period.

  • Click on "Next" to continue with the installation process.

 

Step 10:

  • The corresponding step in the Installation process is choosing the installation directory. By default, the application is installed in home/<user>/ManageEngine/Analytics Plus directory. If you want to change the installation directory, then click the "Choose..." button and choose the installation folder.

  • Once the desired path is selected,click OK and then click on "Next".

Note: Installing under root user is not supported currently.

 

Step 11:

  • Enter the Web Server Port Number to run the web server. The default port number provided is 8443. If you already have another application running in that port, then enter the port number which is free and can be used to run the web server.

  • Click on "Next" to continue with the installation process.

 

Step 12:

  • Enter your details such as Name, contact Email Address, Phone Number (helps in making calls for immediate support), Company Name. The Email Address is a mandatory field.

  • Click on "Next" to proceed with the Installation process.

 

NOTE: This email address will be associated with the default user "administrator". This User alone will have the privilege to create databases, users, etc.,

 

Step 13:

  • The details that you have provided in the installation process are displayed for your confirmation.

  • If the information that is displayed is correct, then click on "Install", else click on "Previous" to make the desired changes and proceed with the installation process.

  • The installation process takes a few minutes. Kindly wait till the process is complete

  • On successful installation, the Successful Installation screen is displayed. By default, the option to Start Server file is not enabled. Check the Start Server option and click on "Done" to start ManageEngine Analytics Plus.

  • Enter the Username and Password to log into the application and start creating reports and dashboards. The default username is "admin" and the default password is "admin".

 

 

Share this post : FacebookTwitter