Configure NetFlow Analyzer with RUCKUS ICX Switch

    RUCKUS ICX 750 supports SFlow flow export. To configure RUCKUS ICX 7550 with NetFlow Analyzer, follow the below commands:

    RUCKUS ICX Switch:

    Note: X.X.X.X is the OpManager Server IP

    device# configure terminal

    device(config)# sflow enable

    device(config)# sflow destination X.X.X.X 9996

    device(config)# sflow polling-interval 60

    device(config)# sflow sample 2048

    Enable sFlow forwarding.

    To enable sFlow forwarding, you must first enable sFlow on a global basis using the sFlow enable command, then enable on individual interfaces or LAG ports or both using the Sflow forwarding command.

    Enable sFlow forwarding on individual interfaces

    device(config)# interface ethernet 1/1/1 to 1/1/8

    device(config-mif-1/1/1-1/1/8)# sflow forwarding

    Enable sFlow forwarding on individual LAG ports

    device(config)# lag test static id 1

    device(config-lag-test)# ports ethernet 1/1/1 to 1/1/8

    device(config-lag-test)# sflow forwarding

    Note: sFlow forwarding is supported on LAG and LACP LAG ports.