# OpManager Plus v12.3 ## Build No - 123158 - June 14, 2018 - OpUtils: Under Inventory, the UI of MAC, IP address and DNS is improved in the ports section by making multiple addresses now visible in a separate slide window when "more..." is clicked. - OpUtils: In the Switch snapshot page under Inventory, the UI of MAC, IP address and DNS is improved in the ports section by making multiple addresses now visible in a separate slide window when "more..." is clicked. - OpUtils: Under privacy settings, Personally Identifiable Information (PII) search and update has been implemented. (PII Search helps identify the PII Details given by the user across various modules. The PII data can also be updated as anonymous to maintain privacy). ## Build No - 123157 - June 14, 2018 - OpManager Plus Plus: The SQL injection vulnerability in "FailOverHelperServlet" for the operation `standbyprobestatus` has been fixed (CVE-2018-9087, CVE-2018-9089). - OpManager Plus Plus: The SQL injection vulnerability in "FailOverHelperServlet" for the operation `getprobenetworkshare` has been fixed (CVE-2018-9088). - 4692934 - The "Integration User" option under "User Management" has been removed. - OpManager Plus Plus: The Interface discovery timeout which was by default set to 5 seconds, will now fetch the timeout value from the SNMP credential. - OpManager Plus Plus: Users can now configure the number of parallel threads for Trap discovery in `threads.conf`. - OpManager Plus Plus: Discovery delay has been introduced for Trap based discovery and the default interval has been set to 20 seconds. The user can configure this delay and set a custom interval in `discovery.properties`. - OpManager Plus Plus: Discovery debug prints have now been introduced for the purpose of troubleshooting. - OpManager Plus Plus: Previously, the SNMPV3 EngineID request was queried only once with a timeout of 5 seconds. Now, the timeout and retries count will be fetched from the credential. - OpManager Plus Plus: Previously, devices running the latest build of Windows 10 were being discovered and classified as Windows 8. This issue has been fixed. - OpManager Plus Plus: Audit logs will now be recorded whenever a user: - Modifies the name of the Business view. - Modifies the name of the Floor view. - Modifies the name of the Rack view. - OpManager Plus Plus: Process names printed in the "Discovery logs" have been modified as "Debug prints" and names with `.exe` have been removed. - OpManager Plus Plus: Previously, the Palo Alto device templates were set with the wrong vendor "APC". This has now been updated as "Palo Alto Networks". - OpManager Plus Plus: Previously, the Interface name and Alias had garbled characters during discovery, when the OS and OpManager Plus Plus had French as the primary language. This issue has now been fixed. - OpManager Plus Plus: Additional SysObjectIDs have been added for the below device template types: - Cisco catalyst296024LT - Cisco 891 - Cisco MDS 9148 ## Build No - 123156 - June 13, 2018 - General: License Agreement has been updated. - General: Promotions related to ITOM Events will be displayed in the UI header after login. - OpManager Plus Plus: Enabling proxy settings blocked APM-Plugin communication. Users were unable to login to the plugin and experienced issues with syncing OPM. This has been handled now. - OpManager Plus Plus: Unable to discover vCenter if proxy settings were enabled in OpManager Plus Plus. Now this has been handled. - OpManager Plus Plus: Disabling proxy settings from client did not take effect directly, and required a server restart. This issue has been fixed. ## Build No - 123150 - June 7, 2018 - OpManager Plus Plus: Audit Information/Logs for Add/Edit/Delete/Associate Operations for URL Monitor has been included. - OpManager Plus Plus: Audit Information/Logs for Add/Edit/Delete User Operations for APM Plugin has been included. - OpManager Plus Plus: Previously, it was not possible to perform actions like Clear/Delete/Acknowledge for URL based alarm from URL snapshot page, alarms view. The mentioned options have been included now. - OpManager Plus Plus: Previously, WMI Credential test for device discovered as Unknown was not possible. This has been fixed now. - OpManager Plus Plus: If both HyperV and WMI devices were being monitored then inside Protocol based Inventory view, the number of devices count was shown incorrectly if VIWMI protocol was chosen. This has been fixed now. - OpManager Plus Plus: Even though vCenter was UnManaged, the VMware Events based alarms were getting raised. This has been fixed now. - OpManager Plus Plus: The field validation for alarm message of threshold violation was not done for Performance monitor, leading to inappropriate confirmation message to user of monitor being saved. This has been fixed now. - OpManager Plus Plus: Once the URL Response Time based only alarm is cleared or deleted, the status of URL monitor is still not updated to Clear. This has been fixed now. - OpManager Plus Plus: With APM Plugin of version 13730 and above, an inappropriate alert is shown to the user asking to upgrade to the latest version of APM Plugin. This has been fixed now. - OpManager Plus Plus: The field validation for Threshold parameters was not done for MSSQL Monitors. This has been fixed now. ## Build No - 123149 - June 6, 2018 - OpManager Plus Plus: Quicklinks to How-to, Technical videos, and FAQs has been introduced in OpManager Plus Plus to help users easily configure settings and to troubleshoot commonly faced issues. - OpUtils: Previously under Dashboard, the edit option in "IP Availability Summary HeatMap" widget only had a drop down list of IPs without their subnet mask. The issue is fixed now by listing IP addresses with their subnet masks. - OpUtils: Previously under Inventory, the edit option in IP address field does not mention the IP Address that is being edited. The issue is fixed now by making the selected IP visible as a header. - OpUtils: Previously under Inventory, the DHCP option shows an empty page when there is no data. The issue is fixed now as it shows sample data which disappears automatically once data is added. - OpUtils: Under Ports page of Inventory, five options such as "Modify IfAlias", "Administratively Disable Interfaces", "Administratively Enable Interfaces", "Exclude Port(s)", and "Include Port(s)" were made available. These actions were not available for the ports listed in switch snapshot page. The issue is fixed now. - OpUtils: Previously under Inventory, the grid is not updated automatically after editing the IP address. The issue is fixed now. - OpUtils: Under tools, there was an issue in the working of Trace Route when resolving the DNS name. This issue is fixed now. ## Build No - 123148 - June 1, 2018 - OpManager Plus Plus: Previously, while configuring "Send Email" in Workflow, the "HTML" mail format option was not working. This has now been fixed. - OpManager Plus Plus: Previously, the option to edit the display name of the IP SLA monitor was unavailable. This option has now been provided. - OpManager Plus Plus: In Probe/Central set up, IP Address field was displayed incorrectly with the probe ID appended at the end. This issue has been fixed. - OpManager Plus Plus: "Custom Dials" option has now been added for UCS devices. - OpManager Plus Plus: Previously, while adding IP SLA Monitor, a proper Field Validation for the Name field was missing. This issue has been fixed. - OpManager Plus Plus: Previously, redirection to the "VoIP Monitor Snapshot" page using the "Top Call Performance by location" widget was not successful. This issue has now been fixed. - OpManager Plus Plus: Previously, clicking the IP SLA Monitor link in the Business View did not redirect the User to the respective Monitor/List page. This issue has now been fixed. - OpManager Plus Plus: WAN RTT Monitor and VoIP Monitor Widgets were missing from the source device of the IP SLA. This has now been included. - OpManager Plus Plus: Previously, the time period for which the reports were displayed was not shown in the IP SLA Widgets. This has now been included. - OpManager Plus Plus: For IP SLA Reports, Widgets and Snapshots, the display name of the destination device will be shown instead of its IP Address. - OpManager Plus Plus: Previously, "Operator" user was not restricted from viewing the URL monitors in the Inventory Page. This issue has been fixed. - OpManager Plus Plus: Previously, "Operator" user was not restricted from being able to modify the background color and the tile color in the 3D floor view page. This issue has been fixed. - OpManager Plus Plus: In Group Chat Module, "Operator" user was not restricted from viewing the list of users, their User ID and Email addresses. This issue has been fixed. - OpManager Plus Plus: In Group Chat Module, the "Delete Post" and "Delete Comment" API was vulnerable to SQL Injection. This issue has been fixed. ## Build No - 123147 - May 31, 2018 - General: Data encryption has been provided for attachments in "Schedule Report Mail". - OpManager Plus Plus: Spreadsheet format has been updated from XLS to XLSX across the product. - OpManager Plus Plus: A disclaimer text concerning privacy has been added in exported PDFs and spreadsheets. This can be disabled/enabled in the system settings page. - OpManager Plus Plus: Alert/Event message showing garbled values has been fixed. - OpManager Plus Plus: In discovery, it was possible to import CSV files that contained HTML content. This issue is now fixed. - OpManager Plus Plus: Previously under "Additional Fields" in "Configuration" module, it was possible to import CSV files that contained HTML content. This issue is handled now. - OpManager Plus Plus: In the Group Chat module, getSocialITPost details API was prone to SQL Injection vulnerability with `postID` parameter. This issue is fixed. - OpManager Plus Plus: Path traversal issue in Group Chat module affecting local drive folders is fixed. ## Build No - 123137 - May 25, 2018 - General: Dashboards are now user-specific and allows users to create their own private dashboards. Apart from this, users with administrator privilege can associate dashboards that are created by them with select users. - NCM: Network Configuration Manager is now **GDPR compliant** with the privacy messages and consent requests displayed in the UI. - NCM: Increased privacy and security through product enhancements. - NCM: Custom column names now populate uniformly throughout the UI after a change. - NCM: More user-friendly with editable Configlet names. - NetFlow: Distributed Edition for latest version has been released. - NetFlow: NetFlow Analyzer is now GDPR compliant with consent requests displayed across various modules in the UI. - NetFlow: Under privacy settings, Personally Identifiable Information (PII) search and update options have been added. (PII Search helps identify the PII Details given by the user across various modules. The PII data can also be updated as anonymous to maintain privacy.) - NetFlow: A step by step guide on How to use NetFlow Analyzer has been added. - NetFlow: Resolve DNS handled for Conversation widget in Device snapshot. - NetFlow: The issue with the wrong granularity values being displayed in Device snapshot page has been fixed. - NetFlow: Search report and Global search report options have been combined together under Search Report. - Firewall Analyzer: Introduced "Audit Report" for all add, delete, and update actions done by Firewall Analyzer user. All the user actions are logged. - Firewall Analyzer: Option to search personal information like Email, phone number and user name across the product and replace them with another user is available under "Privacy Settings". - Firewall Analyzer: "Security Audit Report" is now available in PDF format. You can export the report in PDF format from client. - Firewall Analyzer: Disclaimer added in exported PDF and CSV to convey availability of Personally Identifiable Information (PII) of GDPR. - Firewall Analyzer: Option to add new Custom Report was not visible in UI. Now the issue is fixed. ## Build No - 123136 - May 22, 2018 - General: Previously, Chinese characters sent as parameter in API were saved as garbled characters. This issue has been fixed. - General: Live chat support has been integrated in OpManager Plus Plus. - General: System Performance status icon has been removed from the header in OpManager Plus Plus. - General: Previously, "Arithmetic Exception" error was thrown during a fresh start of OpManager Plus Plus. This has now been fixed. - General: Triggering an API call for creating a dashboard without choosing any widget is restricted to the web client. - General: In edit widget page, same value cannot be given in two different criteria. This has been fixed. - General: Updating a widget without widget name has been fixed. - General: Previously, when adding the first domain, it was not listed in the Windows Domain until the page was reloaded. This issue has been fixed. - General: In global search, NCM-Compliance was not redirecting and the Subnets results were not listed. This issue has been fixed. - General: In global search, showing of undefined value in add-on details from search suggestion has been fixed. - General: In global search, Device notes were not listed out in the search if the list count is more than 10. This issue has been fixed. - General: Previously, PostgreSQL to MSSQL migration kept failing due to mismatch of datatype in "Alert" table and "Event" table. This issue has been fixed. - General: License expiry alert mail will be sent with an interval of 5 days between each reminder for the last 15 days and the final remainder will be sent a day before the license expires. - General: UI Notification displaying license expiry duration in the header has been limited to the last 30 days. - OpManager Plus Plus: Option to export and download "Availability Statistics" as PDF and XLS is provided for all monitors including Windows Service Monitors, Service Monitors, Exchange Service Monitors, AD Service Monitors, MSSQL Service Monitors and Process Monitors. - OpManager Plus Plus: Option has been added to view "Real Time Monitor Graphs" for all the Performance monitors that are available as Dials inside snapshot page. - OpManager Plus Plus: Saving the Hardware Monitor specific settings was prone to SQL Injection vulnerability. This has been fixed now. - OpManager Plus Plus: For Process and Service Monitors snapshot page, the selection of Custom Time Period didn't have any effect and used to show the same details based on previously selected time period. This has been fixed now. - OpManager Plus Plus: Previously, when WMI credential used for monitoring WMI device had space character in its password, the monitored device was experiencing account lock out issue. This has been fixed now. - OpManager Plus Plus: Previously, File/Folder monitoring was not generating alerts even if the file was modified, especially in cases where the monitored device machine had different date formats. This has been fixed now. - OpManager Plus Plus: In Event Log Monitoring, if the configured message field had "tab space" character, the generated event log message was not displayed properly. This has been fixed now. - OpManager Plus Plus: Previously, Performance monitors' XLS reports were generated with garbled characters for non-English languages. This has been fixed now. - OpManager Plus Plus: While configuring Event Log Monitors, field validation for Event ID field was not done. This has been fixed now. - OpManager Plus Plus: Unit for monitors were not shown for File/Folder graphs' tabular view. This has been fixed now. - OpManager Plus Plus: Language localization for "Edit Discovery Profile" and "Never Suppress Alarm" operation specific keys were incorrectly updated for Japanese language. This has been properly updated now. - OpManager Plus Plus: Under Inventory Reports, for "Threshold Details of Devices" report, VMware and HyperV specific Monitors' threshold details were not listed. This has been fixed now. - OpManager Plus Plus: Previously, RuleEngine Re-Run or discovery/rediscovery of device was not getting updated for MSSQL Monitors, even though they were configured in RuleEngine Actions. This issue has been fixed. - OpManager Plus Plus: While mapping IP to VirtualMachines from vCenter/ESXServer/HyperV/Xen Servers snapshot pages, only IP was allowed previously. Now hostname is also allowed. - OpManager Plus Plus: Previously, if an incorrect parameter value for Protocol was passed for updateProcessTemplateDetails API, proper error was not thrown. This has been handled now. - OpManager Plus Plus: In Monitors Tab under Snapshot Page, columns were not being sorted as per data type. This issue has been fixed now. - OpManager Plus Plus: In "Notification Profile" message box, language localization value for Chinese language has been updated for the message property. - OpManager Plus Plus: In Add/Edit File Monitor under Settings page, language localization value for Japanese language has been updated. - OpManager Plus Plus: OpManager Plus Plus agent was getting crashed due to memory leak in the agent while reading the registry data for monitoring. This has been fixed now. - OpManager Plus Plus: In Performance Monitor Graph page, "Last month" time period option has been added. - OpManager Plus Plus: In the device snapshot page, PDF option for Single monitor graph page was not working properly. This issue has been fixed. - OpManager Plus Plus: Test URL option from URL snapshot page failed after the first try. This issue has been fixed. - OpManager Plus Plus: Previously, users were able to select/deselect the listed Event Log rules while associating it to device from snapshot page even without enabling Event Log Monitor Interval. This has now been fixed. - OpManager Plus Plus: Windows Services from device were not retrieved while configuring Workflow with Restart Service action if device credential had special characters. This has been fixed now. - OpManager Plus Plus: Unauthorized SIF Activity (Support Information File) has been restricted and can be accessed only using the admin account. - OpManager Plus Plus: Notification Profile severities will not overwrite Device Misses 1/3/5 Polls profile Criteria selection any more. - OpManager Plus Plus: `+` symbol in the beginning of EMail-Id for Mail Server Settings and Notification Profile is supported now. - OpManager Plus Plus: Previously, Command results of Run Program/System Command Notification Profile appended to alert message were not properly shown. This issue has been fixed. - OpManager Plus Plus: Run Program/System Command Notification profile's message variables given in next line are not taken as arguments while executing commands on notification profile trigger. This issue has been fixed. - OpManager Plus Plus: In Settings page, "Mobile number" was shown even after deleting the App SMS settings. This has been fixed. - OpManager Plus Plus: Previously, trying to uninstall OpManager Plus Plus Central failed with an error popup. This has now been fixed. - OpManager Plus Plus: Previously, installing standby OpManager Plus Plus with invalid credentials of primary OpManager Plus Plus resulted in the setup getting installed as Standalone OpManager Plus Plus with PGSQL backend. This has now been fixed. - OpManager Plus Plus: Previously, installing OpManager Plus Plus with MSSQL DB as backend by providing existing database name resulted in the setup getting installed with PGSQL backend. This has now been fixed. - OpManager Plus Plus: Previously, in Alarm escalation rule, entering multiple mobile numbers, each separated by a comma was not possible. This option has been added. - OpManager Plus Plus: SSH Discovery will fetch the DeviceType from login message based on availability. - OpManager Plus Plus: In reports, the "Server Health Report monitors" name i18n has been updated now. - OpManager Plus Plus: Users can now select multiple SNMP trap processors and delete them in bulk using the "multiple delete option". - OpManager Plus Plus: Search option for SNMP trap processor is now enabled where the user can search trap processors based on either name or OID. - OpManager Plus Plus: Multiple delete option is now enabled for unsolicited traps, where the user can select more than one trap and delete them. - OpManager Plus Plus: Search option for Unsolicited traps is now enabled. - OpManager Plus Plus: A new option is provided in the widget Edit page to enable and disable the Widget Dials. - OpManager Plus Plus: Previously, while adding a rule in Rule Engine, "criteria" drop down field was not populated correctly. This issue has been fixed. - OpUtils: The Bandwidth monitoring tool, which measures the network traffic utilization/bandwidth usage both at the interface level and at the device level, has been brought back under inventory. - OpUtils: The Bandwidth monitoring tool is enhanced with the capability of generating alerts based on the configured threshold violation and the same can be notified through email. - OpUtils: Previously under Oputils option, the SPM General settings could not be saved. This issue is fixed now. - OpUtils: Previously under Inventory, the option to edit a switch in Switch Port Mapper was not working. This issue is fixed now. - OpUtils: In the Network Scanner page under Settings, when deleting multiple IP Address(es) after selecting them, an error message was thrown saying "Nothing is selected to delete". This issue has been fixed and multiple IP address(es) can be batch deleted. - OpUtils: Under "Short Summary" page in Inventory, "Subnet summary", "IP summary", and "Switch summary" title was displayed. This has been removed. - OpUtils: The "Device Type Summary" widget in Dashboard has been renamed to "OS Type Summary" as it represents the OS type installed in the device. - OpUtils: Constraints have been added to check if the "Custom column" name is numeric. An error message will be displayed stating "Invalid Custom Name" in case the name is numeric. - OpUtils: In the MAC Address Resolver page under Setting tools tab, "IP to MAC" and "MAC to IP" were displayed in two different lines due to a minor UI alignment issue. This has now been fixed. - OpUtils: In the Credentials page under SPM in settings, editing an existing credential redirected the page to Discovery's Edit credential page. This issue has been fixed. - OpUtils: Under Basic settings, Database Maintenance option has been removed for OpUtils installation. - OpUtils: In the Scope page for DHCP under Inventory, the "Scope State" column in the table contains two values: "Enabled" and "Disabled". The "Disabled" option will now be highlighted in red color. - OpUtils: In the "OS Type Summary" widget, previously called "Device Type Summary", the "%" symbol was not displayed in the value when hovering the mouse over it. This issue has been fixed. - OpUtils: The SNMP graph tool, which is used to gather real time data and generates a graph for any SNMP IP node, has been brought back under SNMP tools of OpUtils settings. - OpUtils: The SNMP graph tool is enhanced with the capability of providing the MIB node information like OID, syntax, description and MIB node properties. ## Build No - 123127 - May 14, 2018 - OpManager Plus Plus: Inbuilt Storage Monitoring support has been added. ## Build No - 123126 - May 8, 2018 ### Firewall Analyzer: Admin Server - Firewall Analyzer: Enterprise edition for 12.3 version. - Firewall Analyzer: Data Migration tool for enterprise edition 8.5 customers to upgrade to 12.3. ### Firewall Analyzer: Standalone/Collector Server - Firewall Analyzer: Compliance reports and Policy/Rule Management support for WatchGuard device. - Firewall Analyzer: Compliance reports and Policy/Rule Management support for SonicWALL device. - Firewall Analyzer: Policy/Rule re-order report for PaloAlto device. ## Build No - 123125 - May 8, 2018 - OpManager Plus Plus: In Mail Server settings, Authentication Details which was mandatory from 123108 has been made optional. - OpManager Plus Plus: Previously, the selected dashboard view was not being highlighted. This issue has been fixed. - OpManager Plus Plus: When OpManager Plus Plus server rebooted, OpManager Plus Plus service failed to start displaying the error "Unable to start PgSql DB". This has been fixed now. - OpManager Plus Plus: Consent Implementation has been enforced for various modules. - OpManager Plus Plus: Under privacy settings, Personally Identifiable Information (PII) search and update has been implemented. (PII Search helps identify the PII Details given by the user across various modules. The PII data can also be updated as anonymous to maintain privacy.) - OpManager Plus Plus: Audit logs will now be recorded whenever a user: - Adds or deletes additional fields. - Rediscovers a device. - Uploads a Google Map HTML file. - Deletes a device from Google Map. - Creates or deletes Business views, 3D Floor views and Rack views. - Creates, modifies, or deletes a Discovery Profile. - Creates or deletes a group in Group chat. - General: Chrome's latest update (66.0.3359.139) caused OpManager Plus Plus to crash when navigating to any graph pages. This issue has been fixed by updating Zoho Charts from version 1.0.5 to 1.0.8. ## Build No - 123124 - May 3, 2018 - OpManager Plus Plus: Option to copy and modify the Business View ("Copy As" option) has been added. - OpManager Plus Plus: Previously, Zoom in/out feature was missing in Business view widget and Maps. This has now been added. - OpManager Plus Plus: Previously, in "edit Business view", device and shortcut count was missing. This has been handled now. - OpManager Plus Plus: Previously, IPSLA monitors were missing in the Business view. This is fixed now. - OpManager Plus Plus: Under Business views, the device status live update was missing when the page was not refreshed. This has been handled now. - OpManager Plus Plus: Earlier there was an issue with deleting and re-adding devices in business view. This has now been fixed. - OpManager Plus Plus: Previously, when changing font type, size or color in business view, the devices were rearranged automatically. This issue has been fixed. - OpManager Plus Plus: Under Maps, "Set as default" option for Business view, List and Dashboard has been added. - OpManager Plus Plus: The back view of the rack was missing in the new version. This is fixed now. - OpManager Plus Plus: Previously, Rack view and 3D floor embedded view was not working. This issue is now fixed. - OpManager Plus Plus: Device status mismatch issue under Rack widgets in Dashboard has been fixed. - OpManager Plus Plus: Previously, in Google map widget, probe option was displayed for Essential build. This has been fixed now. - OpManager Plus Plus: Interface port status icon in inventory list view has been added. - OpManager Plus Plus: Users can now view device category specific dashboards in the inventory page. - OpManager Plus Plus: Set as Default view has been added for Inventory Device and Interface List. - OpManager Plus Plus: Users can enable or disable the Group chat, Rack and 3D floor view features under System Settings. By default Group Chat feature has been disabled. - OpManager Plus Plus: Graph were not displayed for Interface Receive and Transmit dials. This has been fixed now. - OpManager Plus Plus: Previously, Interface Bandwidth Report schedule would not be generated for the given time period. This has been fixed now. ## Build No - 123123 - April 26, 2018 - NCM: Compliance page has been added in left menu bar for quick access. All compliance-related functionalities are now available under this page. - NCM: Now, you can share Custom Device Templates to NCM Administrators worldwide in "Device template >> Custom >> Share". - NCM: Additional hardware information for Cisco devices is now displayed in the Device Snapshot page under "Inventory" tab. Other vendors will also be supported in the near future. - NCM: You can now search devices by providing their hardware details, in "Inventory >> Devices >> Search by hardware details" using the filter icon on the top-right corner. - NCM: Device selection list is sorted in "Configlets Execution" and "Schedules" pages with the IP addresses of the devices. - NCM: "Should contain exact set" in Compliance rule criteria is now fixed and executes properly. - NCM: The Rule Compliance page under MSSQL now displays the necessary data. - NCM: The "%" symbol in labels of configlet parameters from "Execute Configlet" page has been removed. ## Build No - 123122 - April 25, 2018 - OpManager Plus Plus: Previously, it was possible to access the attached HTML files in GroupChat. This issue has been fixed. - OpManager Plus Plus: In the GroupChat module, getActivityData API was prone to SQL Injection vulnerability. This issue has been fixed. - OpManager Plus Plus: In Credential module, Stored Cross-site Scripting (XSS) vulnerability has been fixed (CVE-2018-10803). - OpManager Plus Plus: Previously, improper file format was accepted during CSV Discovery. This issue has been fixed. - OpManager Plus Plus: Previously, Discovery profile name is vulnerable to Cross-site Scripting (XSS). This issue has been fixed. ## Build No - 123121 - April 24, 2018 - OpManager Plus Plus: In the Add/Edit Performance Monitor page under Device Snapshot and in Device Template page, Regex pattern threshold field length has been increased from 50 to 100. - OpManager Plus Plus: In the Add Performance Monitors page under Device Snapshot and in Device Template page, general monitors were not listed for addition. This has been fixed now. - OpManager Plus Plus: While updating SSH credential from global credential and device snapshot page, SSH key authentication file was stored in an incorrect path. This has been fixed now. - OpManager Plus Plus: Under System settings page, a unique SysName option has been provided to avoid multiple interfaces of the same device being discovered as new devices. - OpManager Plus Plus: Previously, option to add a single device using device name was missing under schedule discovery profile. This has been added now. - OpManager Plus Plus: Previously, Windows 10 device was discovered as Windows 8 via SNMP. This has been fixed now. - OpManager Plus Plus: Previously, in the device snapshot page, the dials displayed data but the Monitors tab was empty. This has been fixed now. ## Build No - 123120 - April 20, 2018 - OpManager Plus Plus: In Quick Configuration Wizard, option to update threshold configuration for a specific group of partition detail monitors for multiple devices has been included. - OpManager Plus Plus: In Quick Configuration Wizard, option to add or update threshold configuration for multiple VMware datastore monitors has been included. - OpManager Plus Plus: UI misalignment in the Quick Configuration Wizard page has been fixed. - OpManager Plus Plus: Previously, in Performance monitor page under Settings, when performing apply and overwrite operation after editing any monitor threshold, Store Data value of the monitor was changed to false by default. This has now been fixed. - OpManager Plus Plus: Previously, from Performance Monitors under Settings page, VMware and Xen Monitors were not getting applied or associated to devices even for VMware and Xen devices respectively. This has been fixed now. ## Build No - 123119 - April 18, 2018 - OpUtils: Under SNMP tools from settings, a tool called MIB node viewer that is used to provide the complete details of the selected MIB has been added. - OpUtils: Under SNMP tools from settings, a tool called MIB module viewer which is used to provide a snapshot of a given MIB has been added. - OpUtils: Under Switch Port Mapper (SPM), the tree view has been added. - OpUtils: The IP snapshot page has been improved by adding missing data and actions. - OpUtils: The MAC-IP list, which was a missing tool, has been added. - OpUtils: Under the Subnet snapshot page, the options to edit and scan has been added. - OpUtils: Under the Subnet snapshot page, the option to delete alerts has been added. ## Build No - 123118 - April 17, 2018 - OpManager Plus Plus: Previously, users were unable to export "Availability Dashboard Report" as PDF and XLS. This issue has been fixed now. - OpManager Plus Plus: Previously, users were unable to schedule "Least and Average availability" for the Availability Dashboard Report. This issue has been fixed now. - OpManager Plus Plus: Users can now navigate to the device snapshot page from HyperV Map. - OpManager Plus Plus: Previously, Last Polled Bandwidth Utilization widget displayed "NaN%" as value. This has been fixed. - OpManager Plus Plus: STP Port Details has been added for devices falling under switch category. - OpManager Plus Plus: Now, users can associate Device Template and Credential for devices from Inventory list. - OpManager Plus Plus: Users can now manage, unmanage and delete devices in BV list view page. - OpManager Plus Plus: Previously, Interface threshold settings text inside interface snapshot page was wrong without units. It is corrected now. ## Build No - 123113 - April 18, 2018 - Firewall: Previously Security Audit page was empty even though the report was generated. Now the issue is fixed. ## Build No - 123112 - April 13, 2018 - OpManager Plus Plus: Option to export "At-a-Glance Report" as PDF and Excel has been included for devices. - OpManager Plus Plus: During Test Monitor, while adding or editing File Monitor, the File path was not displayed. This has been fixed now. - OpManager Plus Plus: Previously, for Folder Monitor Graphs, Y-axis units were not displayed. This has been fixed. - General: Previously under Reports/Settings, when the page was either refreshed or when a new tab was opened, the last opened tab was hidden. This issue has now been fixed. - General: While refreshing the Inventory page, some sub headers went missing. This issue has now been fixed. ## Build No - 123111 - April 11, 2018 - General: Previously, Cookies were prone to Cross-site Scripting (XSS) Vulnerability and they were unsecure for HTTPS protocol. This issue has been fixed. - General: Clickjacking vulnerability has been fixed. - OpManager Plus Plus: Previously, unauthorized access to APIKey from APM Plugin was possible due to a vulnerability issue. This has now been fixed. - OpManager Plus Plus: Modifying or Deleting users in OpManager Plus Plus was not being reflected inside APM Plugin. This issue has been fixed. - OpManager Plus Plus: Previously, APM plugin was not getting started when OpManager Plus Plus with MSSQL Database was using Windows Authentication for database connectivity. This issue has been fixed. ## Build No - 123110 - April 10, 2018 - OpManager Plus Plus: The alignment issue with the columns of Event Reports and Alert Reports PDF is now fixed, so that XLS and PDF reports match. - OpManager Plus Plus: Operator cannot create or schedule a report anymore. - OpManager Plus Plus: Previously, when SDP details contained special characters, there were issues while editing the "Log a ticket" notification profile. This has been fixed now. - OpManager Plus Plus: Issues with downloading PDF reports have been fixed. - OpManager Plus Plus: "No data available for this period" alert message is displayed when there is no data in integrated report. - OpManager Plus Plus: Data older than a week is now available in the Interface report builder. - OpManager Plus Plus: Under "Audit" in Reports, users can now view the logs for scheduled operations. - OpManager Plus Plus: Under "Audit" in Reports, users can now view the logs for PDF and XLS export operations. - OpManager Plus Plus: Audit Operation for Device Specific Deletion and Updation has been handled. - OpManager Plus Plus: While raising event flood warning in OpManager Plus Plus, the message will now specify whether the flood is due to traps or event logs. - OpManager Plus Plus: Previously, NCM count was not updated in the central server when deleted from the probe. This has been fixed now. - OpManager Plus Plus: The NCM plug-in URL has been removed in DeviceExpert Change Management and DeviceExpert Operation Failure traps. - OpManager Plus Plus: Previously, the custom category count of network device's alarms was displayed wrongly in the Network tab under Dashboard. This has been fixed now. - OpManager Plus Plus: In version 11600, under Data Diagnostics, the Central and Probe table comparison page was missing previously. This has been fixed now. - OpManager Plus Plus: While migrating from Linux Essential To Enterprise Edition, the migration failed due to the presence of `\` in `MigrateToEnterprise.sh` file. This has been fixed now. ## Build No - 123109 - April 5, 2018 - OpUtils: Under Reports option, the missing reports of the DHCP has been added. - OpUtils: Previously under Inventory, the option to edit a group of switches in SPM was not available. The issue is fixed now. - OpUtils: Previously under OpUtils settings, the port history was in General tab. This is moved to cleanup policy tab now. - OpUtils: Under Inventory, the category sub filter in port field has added an "administrative disabled/enabled" option. - OpUtils: Previously under Inventory, the "Add to SPM" option did not display a proper Success/Error message in UI. The issue is now fixed. - OpUtils: Under Inventory, the category sub filter "NIC type" table has been updated to match the IEEE OUI list. ## Build No - 123108 - April 4, 2018 - OpManager Plus Plus: XML External Entity (XXE) Processing attack affecting import of License, Script Template, Device Template and Workflow has been fixed. - OpManager Plus Plus: Previously, in Mail Server Settings and Radius Server Settings, the password was being shown as `not_to_display`. This issue has been fixed and now the password field will be left blank by default. - OpManager Plus Plus: Cross-site Scripting (XSS) attack has been fixed. - OpManager Plus Plus: SQL injection in Submit DB Query Page has been fixed. ## Build No - 123107 - April 3, 2018 - NetFlow: "Guest" user privilege has been added for NetFlow installation. - NetFlow: The issue with the wrong bandwidth value appearing in the "Overview" tab in Interface/Interface Group/IP Group snapshot when custom time period is selected has now been fixed. - NetFlow: Enhanced raw data dump to avoid increase in `tmp/flow_log.txt` file size. ## Build No - 123106 - April 2, 2018 ### Bug Fixes in NCM - 4439431 - Know which config version is baseline in config diff view. The Config version that is baseline is mentioned as "Baseline". - 4550432 - Layout of NCM Nipper reports has been revamped. - 4571167 - Issue while finding SysOID has been fixed. ### Enhancements in NCM - View SNMP profiles from System Location and Description pages. - Select specific SNMP profiles to be used while updating location and description details for devices. - Add devices as unmanaged if the total number of devices exceeds the license limit. - More devices are supported by default with the additional SysOIDs. - I18N keys are now available. - Minor UI enhancements. ### New Feature in NCM - Terminal - Terminal page can be used to open a terminal to any device in the network. - Terminal connection to the inventoried devices can be opened under *Settings >> NCM >> Inventoried*. - For devices that support terminal function but are not included in Inventory, the session can be initiated by *Settings >> NCM >> Terminal >> Custom*. - All the terminal sessions will be logged and can be viewed in *Settings >> NCM >> Terminal >> Audit History*. ## Build No - 123105 - March 29, 2018 - NCM: Network Configuration Manager now scales more. A single server supports 10,000 devices. If you need to manage more than 2,000 devices, configure the number of parallel job count to a minimum of 50 in "Settings >> NCM >> Server settings" and restart the server. - NCM: You can trigger a configuration backup operation for any number of devices in a single schedule in "Settings >> NCM >> Schedule". - NCM: You can now apply the credentials for any number of devices successfully from "Device Group" page under Inventory section. ## Build No - 123104 - March 28, 2018 - OpManager Plus Plus: Previously, "Schedule Report" did not work for other languages. This issue is now fixed. - OpManager Plus Plus: Previously, the "Schedule Report" option was missing in the snapshot pages of all performance monitors, availability, interface metrics, Packet loss, response time, Device at-a-glance reports, URL and Script Templates. This has been fixed now. - OpManager Plus Plus: SDP Device asset information will now be in the snapshot page of OPM for all the devices synced with SDP. - OpManager Plus Plus: The issue with the `ping.properties` file to view device availability for non-English installations is now fixed. ## Build No - 123093 - March 26, 2018 - OpManager Plus Plus: 100% CPU Utilization issue due to AppSMS has been fixed. ## Build No - 123092 - March 22, 2018 - Firewall: Default reports enhanced with drill down option to second and third level. Particularly for "Unknown Protocols", you can drill down up to raw log level. - Firewall: "End User" feature moved to "Firewall Inventory" tab. You can get "End User" details from "Users" Tab. - Firewall: "Rule Management" and "Compliance Reports" files stored in Firewall Analyzer server directory are encrypted now. - Firewall: User information is encrypted at the database storage. - Firewall: "CSV Export" option is available for "Rule Management" reports. - Firewall: "Scheduled Report" mail format is enhanced to show properly aligned mail content. - Firewall: Support - 4458020: In "Change Management" report, new column has been added to show the IP address of user from which configuration changes were made. - Firewall: Support - 4429668: "Admin" report is available for Huawei Firewall. You can view user login, logout and command executed reports. - Firewall: Support - 4477638: Fixed the issue of incorrect data shown in "Policy Optimization reports" for some PaloAlto devices. - Firewall: Support - 4519337: Fixed the issue of not fetching configuration files from SonicWALL firewalls due to incorrect SCP command. - Firewall: Support - 4497009: Fixed issues in "Denied Events" and URL log parsing for Juniper SRX devices. - Firewall: Support - 4510780: Fixed the issue of wrong time period shown in i-Filter reports data, due to non-processing of time stamp available in the logs. - Firewall: Support - 4496764: Fixed the issue of mismatch in rules count of unused rules and total rules displayed for some PaloAlto firewalls. - Firewall: In PaloAlto firewall "Policy Overview" page, no data was displayed when clicked on some source and destination objects. This issue is fixed. - Firewall: Fixed the issue of no data display in "Total Bytes" column in Trend Micro device reports, due to non-processing of byte value available in the logs. ## Build No - 123091 - March 20, 2018 - OpManager Plus Plus: Added an option to switch menu bar alignment into vertical or horizontal. - OpUtils: The DHCP Scope Monitor of the SNMP tool is enhanced in a way that helps to monitor the DHCP scopes of a given IP address or DHCP server name and scans intermittently based on the scheduler profile created by the user. It also provides an email alert to the user when an IP address in the DHCP scope falls below a specified count. - OpUtils: The Network Monitor tool is updated to monitor the response time and packet loss of selected devices, creates a history of details that can be viewed by the user. - OpUtils: The System Details Update of Network monitoring tool has been enhanced in such a way that it is made possible to edit system details of specific devices like sys name, sys location, sys contact and update these details from the remote device itself. The updated status can also be viewed from the remote device. - NCM: 100% CPU Utilization issue due to Syslog flooding has been fixed. - NCM: 100% CPU Utilization issue due to Fortigate Firewall backup has been fixed. ## Build No - 123090 - March 19, 2018 - General: OpManager Plus Plus now supports SMS notifications via HTTP SMS Gateway and SMPP server. - General: 4028582 - Now, SMS server settings can be deleted in the UI. - General: Previously, server secret was visible in Radius Settings. This option is now hidden. - General: User access Level can be changed by Operator using API. This issue has been fixed. - General: 4358794 - Product version showed undefined in UI when NCM folder existed under OpManager Plus Plus. This issue has been fixed. - General: 4447605, 4421517, 4405385, 4382147 - Option to apply `.XML` file type in license has been added. - OpManager Plus Plus: 4479975, 3924891 - Previously in Script Template, the HTML content had visibility issues. This has been fixed. - OpManager Plus Plus: Device name was not being updated when Last Polled returned null value in CPU/Memory/Disk and Bandwidth utilization widget. This issue has been fixed. - OpManager Plus Plus: Previously, Script Template had XSS vulnerability issues. This has been fixed. - OpManager Plus Plus: A new tray icon has been implemented for essential, central and probe setup. - OpManager Plus Plus: Under User Management, the user photo was not deleted from the saved folder even when the user profile was deleted. This issue has been fixed. - OpManager Plus Plus: Option to enable or disable DB query from system settings screen has been added. Based on the option selected, the DB query inside support is shown or hidden to the user. By default, the option is disabled. - OpManager Plus Plus: Partial masking of the API Key in UI has been implemented. - OpManager Plus Plus: Audit implementation for various modules like rebranding, Add/Edit/Delete Domain, Notification, License and Support has been done. - OpManager Plus Plus: 4244642 - Previously, Clickatell notifications were not working and displayed "Clickatell authentication failure" error message. This issue is fixed now. - OpManager Plus Plus: 3893820 - SMS Notifications were not received when multiple mobile numbers were given in the SMS Notification profile. - OpManager Plus Plus: 4252424 - Failover: For a business view created in the primary server with a custom image as background, the image was not loaded when the standby server took over. This issue is now fixed. - OpManager Plus Plus: 125561 - Failover: Primary server's configuration files were not copied to Secondary. This issue is now fixed. - OpManager Plus Plus: 3835548 - User created dashboards can now be renamed in OpManager Plus Plus. - OpManager Plus Plus: 4032958 - On embedded "Heat Map widget", the tooltip was not displayed. This has been fixed now. - OpManager Plus Plus: 3660586 - Updated `commons-collections` JAR to version 3.2.2 due to Remote Code Execution vulnerability in older version. - OpManager Plus Plus: 4113354 - In the "Send Email Notification" profile, the length of "To Email Address" field is now increased from 255 to 500 characters. ## Build No - 123086 - April 19, 2018 - General: Failed to load the client if the MSSQL database collation is `Danish_Norwegian_CI_AS`. This issue has now been fixed. ## Build No - 123084 - March 15, 2018 - OpManager Plus Plus: Thresholds for Response time and Packet loss can be set for multiple devices. - OpManager Plus Plus: New Availability graph has been introduced in Device snapshot page, Availability dial, History to show the device up and down status using a line graph. - OpManager Plus Plus: GPS coordinates will be shown in Device summary tab if the device has been added to Google Maps. - OpManager Plus Plus: Previously, users were unable to add string monitor with a string threshold in Device Templates. This is now fixed. - OpManager Plus Plus: The "Configure Interface" option was not displayed for routers. This has been fixed now. - OpManager Plus Plus: Interface Reports are now available by default on Interface snapshot menu. - OpManager Plus Plus: SNMP text was displayed for Default dials for availability, Response time and Packet loss. This has been fixed now. - OpManager Plus Plus: Users can able to discover and add device without credentials in OpManager Plus Plus. - OpManager Plus Plus: Previously, SNMP v1/v2 credential mismatch error was thrown while adding credential in discovery wizard page. This has been fixed now. - OpManager Plus Plus: Search option has been added for interfaces in device snapshot page. - OpManager Plus Plus: Table values were not displayed for interface error, discard rate, Traffic Utilization graphs. This has been fixed now. - OpManager Plus Plus: Previously, "Export as PDF" did not work for all the time periods for the "Interface Bandwidth Report" and the "Interface At a Glance Report". This is fixed now. - OpManager Plus Plus: Previously, Interface graph time format issue occurred when a period 7 days or 30 days was selected. This issue is fixed now. - OpManager Plus Plus: Users can now navigate to the device snapshot page from the interface snapshot page toolbar. - OpManager Plus Plus: Previously, users were unable to align custom HTML widget, when multiple iframes were called. This has been fixed now. - OpManager Plus Plus: While creating a business view in IE, navigating to the Multi select mode made the device name disappear. This issue has been fixed now. - OpManager Plus Plus: XSS vulnerability issue while importing Additional fields has been fixed. - OpManager Plus Plus: SQL Injection vulnerability has been fixed for Downtime scheduler. - OpManager Plus Plus: Downtime report not showing the status of currently down devices has been fixed. - OpManager Plus Plus: Previously, wireless devices were not getting pushed to NCM. This has been fixed. - OpManager Plus Plus: Previously, when a user generated weekly reports, the days of the week were plotted as numbers. This issue is now fixed. - OpManager Plus Plus: The issue with the `ping.properties` file to view device availability for non-English installations is now fixed.