# OpManager v12.3 # Build No - 123053 - January 19, 2018 - OpManager: Under business views, the link traffic status colors did not change based on the utilization previously. This issue is now fixed. - OpManager: In the business view widget, the links to access the devices were missing. This issue is fixed now. - OpManager: Auto-refresh was not working for the dashboards when any tabs from Applications under Servers were clicked. This has been fixed now. - OpManager: In Business Views created in before version 12(old UI), during mouse over, the device details pop-up in the dashboard continued to display until the page was refreshed(in version 12 and above). This issue is fixed now. - OpManager: Previously there was no option to change the name of the Rack and Floor View. This is fixed now. - OpManager: The issue with the Business view widget resizing is fixed now. - OpManager: While accessing OpManager web client from remote servers, there was a time discrepancy issue with graph and data display when hosted on UTC time zone. This has been fixed now. - OpManager: Under Link Properties of Business Views, while getting status from NFA The color of the connection mismatched with that of the legend. While clicking on the connection if the utilization was 5% for IN and 11% for OUT, the connection was displayed in green instead of blue. This is now fixed. - OpManager: Under Business View, upon mouse rollover on NFA links, it did not display the selected data type in the link Properties of the connection. This has been fixed now. - OpManager: Under Business View, NFA Source and destination links were not retained while editing the link. This issue is now fixed. - OpManager: In Network discovery, the addition of Partition and disk space monitors failed for CLI credentials. This issue is now fixed. - OpManager: In VLAN graphs, the data displayed in the graph was not in order. This issue is fixed now. - OpManager: Under Monitoring tab, in Performance monitors, the description was not displayed for custom monitors. This issue is now fixed. - OpManager: Under Monitoring tab, in Performance monitors "Delete" option is now added to custom monitors. - OpManager: In Device rediscovery, Unmanaged devices cannot be rediscovered now. - OpManager: In Quick Configuration Wizard, Dependency devices listing was not sorted previously. This issue is now fixed. - OpManager: In Device Templates, the issue with matching SysOID criteria and Custom OID criteria are fixed now. # Build No - 123052 - January 17, 2018 - OpManager, NetFlow Analyzer, Network Configuration Manager, Firewall Analyzer and OpUtils: The possibility to fetch user details through ConfServlet has been fixed and is secured now. - NetFlow: Schedule reports for report period as "Previous Week" shows data for current week. This issue has been fixed now. # Build No - 123051 - January 12, 2018 - OpManager: Previously, under group chat option, the Business view users were able to see the alarm discussions for all devices including the devices for which they had no access to. This issue is fixed now. - OpManager: Previously, the Discussions option under group chat had an issue in viewing the full thread. This issue is now fixed. - OpManager: Previously, in Business view option, the devices, which were not monitored, were showing their status as clear. This issue is now fixed. - OpManager: Previously, the option to edit a link in a Business view was not working. This issue is now fixed. - OpManager: Previously, the Business view status under maps which showed "wrong severity" is fixed now. - OpManager: Previously, in business view option, the list view device status was displayed as "unknown" instead of unmanaged. This issue is now fixed. - OpManager: Previously, in business view option, the map view device status was displayed as "unmanaged" instead of "device not monitored". This issue is now fixed. - OpManager: Under Maps, the device status was displayed as "clear" instead of the "device not monitored" in the graph of business views. This has been fixed now. # Build No - 123050 - January 9, 2018 - Under Alarms tab, I18N for "No Data" & "No Alarms for selected Period" was not present previously. This issue is now fixed. - Under Reports, the sorting feature was not working. When the first column (min) was sorted, the other columns (max,avg) change randomly. This issue is now fixed. - Previously, sorting feature did not work for device names in the "DISK USAGE BY DRIVES" report. This issue is now fixed. - Under reports, while selecting the "last date" in the monthly schedule, the scheduler was not able to identify the last date for that particular month. This issue is now fixed. - After upgrading to the latest version, the scheduled reports were not listed. This issue is now fixed. # Build No - 123049 - January 8, 2018 - OpUtils: Filters have been added in the device snapshot pages of Ports and IP Address. - OpUtils: 4249914 - Under reports, the "Export" option is now more visible on the top of the page. - OpUtils: Previously in the rogue dashboard, 1000 recently discovered devices were displayed. Because of this, the page loading time had increased. This issue is fixed by reducing the number of recently discovered devices from 1000 to 100. - OpUtils: Under Inventory, wrong tab details were displayed under sub filters, in the left side of the page. This is now fixed. - OpUtils: 3740821 - Under port snapshot page, the field "Physical Location" can now be edited. - OpUtils: 4120052 - Previously, DHCP Scopes scanning was not completed due to null values in clientinfo. This issue is now fixed. - OpUtils: Previously, when license count was 3, users were able to add 4 users (Including admin), but then OpUtils displayed the license activation page in the next login session. This issue is now fixed to add only 3 users including admin. - OpUtils: After deleting DHCP, the page was not refreshed. This issue is now fixed. - OpUtils: Under IP address tab in the inventory, the asset tag data was missing previously. This is now fixed. # Build No - 123048 - January 5, 2018 - OpManager: The Delete/Exit action performed on any process template was executed on all the process templates with the same name but different path arguments. This has been fixed, and now the action will be performed only on that specific process. - OpManager: Language localization has been done for threshold column values inside the performance monitors Page. - OpManager: Under downtime widgets, the downtime of URLs, services, devices, WAN Links were displayed as zero seconds. This issue is fixed now. - OpManager: For default virtual reports, the user was able to view devices that he did not have access to. This issue is fixed now. - OpManager: In some cases, the discovery of HyperV-Servers failed when the same HyperV-Server was deleted and discovered again in a short span of time. This has been fixed now. - OpManager: If the user tried to dissociate all the devices associated to a certain Windows Service Monitor, a false alert was displayed to the user to select at least one monitor. This has been fixed now. - OpManager: While adding a new windows service monitor from the device snapshot page, the consecutive value and restart actions value were set to default values for the already associated monitors to that device. This has been fixed now. - OpManager: It was not possible for the user to add any recently deleted VMware/HyperV/Xen monitor to that specific vendor based virtual server from the snapshot page. This has been fixed now. - OpManager: HyperV specific monitors were added to the normal physical server for Microsoft devices from device snapshot page. This has been fixed now. - OpManager: While mapping any new device that was monitored in OpManager to "Not Monitored VM's" in a vCenter/ESX Server snapshot page, the existing display name of that device was changed. This has been fixed now. - OpManager: While adding a new windows service monitor from the device snapshot page by getting a new list from the actual device, the existing associated monitors were deleted from the OpManager when those monitors were not available in the actual device. This issue is now fixed. - OpManager: The inconsistency in allowing some special characters in the URL Display when added during CSV file Import and from the web client is now fixed. - OpManager: Previously, while adding URL monitors, the value 0 was allowed for "Time-Out" and "Consecutive Times" field. This has been fixed now. - OpManager: While associating a URL Template to the device using RuleEngine, the consecutive time value for the monitor was not updated. This has been fixed. - OpManager: While configuring a URL monitor from the device snapshot page and the URL template page, the "Request Parameters" field did not accept more than one parameter. This has been fixed now. - OpManager: In the Application Monitors page, for AD/Exchange/MSSQL value with repeated digits for threshold or poll interval fields were not allowed. This has been fixed now. - OpManager: Previously language localization was not done for the "Path Not Found" text while executing "Test Monitor" from the "Add Folder Monitor" page. This has been fixed now. *(Content continues with subsequent build notes exactly as provided in the source document, preserving all sections, headings, and bullet points through OpManager v7 — Build No - 7100.)*