# UPS Health Monitoring and Alerts The UPS monitoring feature in OpManager automatically classifies the UPS devices in your network and associates a few in-built health monitors (that collects data on battery health, battery status, runtime, etc) upon discovery. These monitors helps in monitoring device specific (UPS) metrics and generate alerts based on the response values of OIDs and severity that are hard-coded. Apart from the above said monitors, there are various performance monitors that are bundled with the device template associated with the respective UPS devices. Any unavailability in the network devices or threshold violation in the respective performance monitors will be notified instantly with the help of alarms and [notification profile](https://www.manageengine.com/network-monitoring/help/configuring-notifications.html) alerts. These thresholds can be configured for severity such as Critical, Trouble, Attention from the respective device template page or the UPS Device Snapshot page. You can also create custom performance monitors similar to the ones that can be created in other categories. [More about configuring thresholds](https://www.manageengine.com/network-monitoring/help/configure-thresholds.html). OpManager queries the below OIDs during status polling in order to monitor the availability and health status of the discovered UPS devices. | Vendor Name | Monitor Name | OID | |---|---|---| | APC UPS | UPS Model | .1.3.6.1.4.1.318.1.1.1.1.1.1.0 | | APC UPS | Link State | .1.3.6.1.4.1.318.1.1.1.4.1.1.0 | | APC UPS | Battery Status | .1.3.6.1.4.1.318.1.1.1.2.1.1.0 | | APC UPS | Battery Runtime | .1.3.6.1.4.1.318.1.1.1.2.2.3.0 | | APC UPS | Battery Health | .1.3.6.1.4.1.318.1.1.1.2.2.4.0 | | APC UPS | Last Test Result | .1.3.6.1.4.1.318.1.1.1.7.2.3.0 | | APC UPS | Output Volts | .1.3.6.1.4.1.318.1.1.1.4.2.1.0 | | APC UPS | Output Current | .1.3.6.1.4.1.318.1.1.1.4.2.4.0 | | APC UPS | Last Self Test date | .1.3.6.1.4.1.318.1.1.1.7.2.4.0 | | Liebert UPS | UPS Model | .1.3.6.1.4.1.476.1.1.1.1.1.2.0 | | Liebert UPS | Link State | .1.3.6.1.4.1.476.1.1.1.1.7.2.0 | | Liebert UPS | Battery Status | .1.3.6.1.4.1.476.1.1.1.1.7.2.0 | | Liebert UPS | Battery Runtime | .1.3.6.1.4.1.476.1.1.1.1.2.1.0 | | Liebert UPS | Output Volts | .1.3.6.1.4.1.476.1.1.1.1.4.4.1.2.0 | | Liebert UPS | Output Current | .1.3.6.1.4.1.476.1.1.1.1.4.4.1.3.0 | | TrippLite UPS | UPS Model | .1.3.6.1.4.1.476.1.1.1.1.1.2.0 | | TrippLite UPS | Link State | .1.3.6.1.4.1.850.1.1.4.1.0 | | TrippLite UPS | Battery Status | .1.3.6.1.4.1.534.1.2.5.0 | | TrippLite UPS | Battery Runtime | .1.3.6.1.4.1.850.1.1.2.3.0 | | TrippLite UPS | Last Test Result | .1.3.6.1.4.1.850.1.1.8.2.0 | | TrippLite UPS | Output Volts | .1.3.6.1.4.1.850.1.1.4.5.1.2.0 | | TrippLite UPS | Output Current | .1.3.6.1.4.1.850.1.1.4.5.1.3.0 | | MGE UPS | UPS Model | .1.3.6.1.4.1.705.1.1.2.0 | | MGE UPS | Battery Runtime | .1.3.6.1.4.1.705.1.5.1.0 | | MGE UPS | Battery Health | .1.3.6.1.4.1.705.1.5.11.0 | | MGE UPS | Last Test Result | .1.3.6.1.4.1.705.1.10.3.0 | | MGE UPS | Output Volts | .1.3.6.1.4.1.705.1.7.2.1.2.0 | | MGE UPS | Output Current | .1.3.6.1.4.1.705.1.7.2.1.5.0 | | UPSV4 | UPS Model | .1.3.6.1.4.1.2254.2.4.1.2.0 | | UPSV4 | Link State | .1.3.6.1.4.1.2254.2.4.5.1.0 | | UPSV4 | Battery Status | .1.3.6.1.4.1.2254.2.4.7.2.0 | | UPSV4 | Battery Runtime | .1.3.6.1.4.1.2254.2.4.7.5.0 | | UPSV4 | Battery Health | .1.3.6.1.4.1.2254.2.4.7.1.0 | | NET VISION | UPS Model | .1.3.6.1.4.1.4555.1.1.1.1.1.1.0 | | NET VISION | Link State | .1.3.6.1.4.1.4555.1.1.1.1.4.1.0 | | NET VISION | Battery Status | .1.3.6.1.4.1.4555.1.1.1.1.2.1.0 | | NET VISION | Battery Runtime | .1.3.6.1.4.1.4555.1.1.1.1.2.3.0 | | LAN MASTERYS | UPS Model | .1.3.6.1.4.1.4555.1.1.3.1.1.1.0 | | LAN MASTERYS | Link State | .1.3.6.1.4.1.4555.1.1.3.1.4.1.0 | | LAN MASTERYS | Battery Status | .1.3.6.1.4.1.4555.1.1.3.1.2.1.0 | | LAN MASTERYS | Battery Runtime | .1.3.6.1.4.1.4555.1.1.3.1.2.2.0 | | ADICOM UPS | UPS Model | .1.3.6.1.4.1.4555.1.1.5.1.1.1.0 | | ADICOM UPS | Link State | .1.3.6.1.4.1.4555.1.1.5.1.4.1.0 | | ADICOM UPS | Battery Status | .1.3.6.1.4.1.4555.1.1.5.1.2.1.0 | | ADICOM UPS | Battery Runtime | .1.3.6.1.4.1.4555.1.1.5.1.2.3.0 | | Powerware UPS | Link State | .1.3.6.1.4.1.534.1.4.5.0 | | Powerware UPS | Battery Status | .1.3.6.1.4.1.534.1.2.5.0 | | Powerware UPS | Battery Runtime | .1.3.6.1.4.1.534.1.2.1.0 | | Powerware UPS | Last Test Result | .1.3.6.1.4.1.534.1.8.2.0 | | Powerware UPS | Output Volts | .1.3.6.1.4.1.534.1.4.4.1.2.0 | | Powerware UPS | Output Current | .1.3.6.1.4.1.534.1.4.4.1.3.0 |