CVE-2020-6967
Description
In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data.
Risk Information
Base Score
9.8
MODERATE
Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS Score
Exploitation Probability
2.1
Associated Vulnerability
| Vulnerability | OS Platform |
|---|---|
| Vulnerabilities CVE-2020-12033,CVE-2020-6967,CVE-2021-22681 are affected in Factorytalk services platform 2.3 | Windows |
| Vulnerabilities CVE-2020-6967 are affected in Factorytalk services platform - | Windows |
Patch Details
No records foundReferences
https://nvd.nist.gov/vuln/detail/CVE-2023-1234