CVE-2021-1586

Description

A vulnerability in the Multi-Pod or Multi-Site network configurations for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an unauthenticated, remote attacker to unexpectedly restart the device, resulting in a denial of service (DoS) condition. This vulnerability exists because TCP traffic sent to a specific port on an affected device is not properly sanitized. An attacker could exploit this vulnerability by sending crafted TCP data to a specific port that is listening on a public-facing IP address for the Multi-Pod or Multi-Site configuration. A successful exploit could allow the attacker to cause the device to restart unexpectedly, resulting in a DoS condition.

Risk Information

Base Score
8.6
MODERATE
Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H
EPSS Score
Exploitation Probability
0.08

Associated Vulnerability

VulnerabilityOS Platform
Cisco Nexus 9000 Series Fabric Switches ACI Mode Multi-Pod and Multi-Site TCP Denial of Service Vulnerability For Cisco NX-OS System Software in ACI ModeNCM
Insufficient Verification of Data Authenticity Vulnerability (CVE-2021-1586)NCM

Patch Details

Click to see the patches provided by ManageEngine for this CVE
Patch IDPatch Description
PATCH-1706155Security Update for Cisco NX-OS System Software in ACI Mode 5.2(1)SV5(1.3b)

References

https://nvd.nist.gov/vuln/detail/CVE-2023-1234
https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2023-1234