# Integrate OpManager with SiliconFlow Connect OpManager to SiliconFlow-hosted language models to generate alarm, device, device group, and problem summaries, script templates, and SNMP OID suggestions without leaving the platform. Setup takes about five minutes and requires only a SiliconFlow account and an API key. The integration works alongside any other configured AI vendor. **Privacy:** To safeguard sensitive data, OpManager applies a [PII masking](https://www.manageengine.com/network-monitoring/help/ai-settings.html) layer before any information is sent to SiliconFlow. Device and user identifiers (including IP addresses, hostnames, and serial numbers) are masked prior to transmission and automatically restored in the response, ensuring generated summaries and scripts remain accurate without exposing sensitive details to the AI vendor. ## Configuration in OpManager To enable AI-generated summaries in OpManager, you must first configure the SiliconFlow integration. This requires generating an API key from your SiliconFlow account and entering it in OpManager to establish a secure connection between the two systems. The base URL used to connect to SiliconFlow depends on which domain your API key is provisioned for. An API key works only with the domain on which your SiliconFlow account was created: accounts created on `siliconflow.cn` use the `cn` domain, and accounts created on `siliconflow.com` use the `com` domain. By default, OpManager uses the `cn` domain (`https://api.siliconflow.cn/v1`). If your account was created on `siliconflow.cn`, skip this step. If your API key requires the `com` domain, follow the steps below before completing the integration: 1. Open the file `serparameters.conf`, located at: `\conf\OpManager\serparameters.conf` 2. Add the following entry: `SILICON_FLOW_GLOBAL true` 3. Save the file, and restart OpManager. After restarting, OpManager will connect to SiliconFlow using: `https://api.siliconflow.com/v1` To revert to the `cn` domain at any time, either set `SILICON_FLOW_GLOBAL` to `false` or remove the entry entirely, then restart OpManager. 1. Go to **Settings → General Settings → Integrations → GenAI → SiliconFlow**. 2. Enter your **Organization Name** (optional). 3. In the **API Key** field, paste the key copied from your SiliconFlow account. ![SiliconFlow integration page with the Organization Name and API Key fields](https://cdn.manageengine.com/sites/meweb/images/network-monitoring/images/siliconflow_integration.png) 4. Click **Fetch Model** to retrieve all models available for the provided API key. 5. Select the desired model from the **Model** dropdown. 6. Set the **Token Count** as required for your environment. Use the following guidance: - **What it controls:** Token Count sets the ceiling on the number of tokens the model can use to generate a response. A higher value helps accommodate more detailed summaries and scripts, if the model generates them. - **Recommended range:** 1,000 to 2,000 tokens for Device Summary, Device Group Summary, All Alarms Summary, and SNMP OID generation; 2,000 to 3,000 tokens for Individual Alarm Summary, Problem Summary, and Script Generation. Do not exceed the maximum output limit of the selected model. - Treat these values as a starting point rather than a fixed rule. The tokens needed depend on the model and how much reasoning it applies. One model may produce a summary in under 1,000 tokens, while a more reasoning-heavy model may need 4,000 to 5,000 tokens for a basic device summary. In general, the ranges above work well. - **Trade-offs:** Higher values increase SiliconFlow usage cost and response time. Values that are too low can truncate the response, especially for features that use more tokens, such as Problem Summary and Script Generation. 7. Acknowledge the data privacy notice and click **Proceed**. ![Model dropdown and Token Count field on the SiliconFlow integration page](https://cdn.manageengine.com/sites/meweb/images/network-monitoring/images/siliconflow_integration_model_token.png) ![Data privacy notice to acknowledge before proceeding with the SiliconFlow integration](https://cdn.manageengine.com/sites/meweb/images/network-monitoring/images/siliconflow_privacy_note.png) 8. Click **Save**. SiliconFlow has successfully been integrated with OpManager. ## AI Settings: assigning vendors per feature After completing the integration, navigate to the **AI Settings** page to control which vendor and model powers each AI feature in OpManager. 1. Go to **Settings → General Settings → AI Settings**. From this page, you can: - **Enable or disable** individual AI features using their toggle. - **Assign a vendor and model** independently for each feature using the **Vendor** and **Model** dropdowns. - **Apply a single vendor and model to all features at once** by enabling the **Apply to all features** checkbox. ![AI Settings page with feature toggles and Vendor and Model dropdowns for each AI feature](https://cdn.manageengine.com/sites/meweb/images/network-monitoring/images/ai_settings_page.png) The following features can be configured independently: | Feature | Description | |---|---| | **All Alarms Summary** | Consolidates all active alarms into a single prioritized summary | | **Individual Alarm Summary** | Analyzes a single alarm for probable cause and remediation steps | | **Device Group Summary** | Summarizes health and performance trends across a device group | | **Device Summary** | Generates a focused health overview for a single device | | **Problem Summary** | Analyzes correlated alarms and identifies the probable root cause | | **Script Generation** | Produces script templates from a natural-language description | | **SNMP OIDs for Performance Monitors** | Fetches relevant SNMP OIDs based on a plain-language description (available from OpManager version 12.9.120 onward) | When multiple vendors (such as [Ollama](https://www.manageengine.com/network-monitoring/help/integrate-opmanager-with-ollama.html), [OpenAI](https://www.manageengine.com/network-monitoring/help/integrate-opmanager-with-openai.html), or [DeepSeek](https://www.manageengine.com/network-monitoring/help/integrate-opmanager-with-deepseek.html)) are configured, each feature can be assigned a different vendor. For example, alarm summaries can run on SiliconFlow while script generation uses a locally deployed Ollama instance. ## AI features powered by SiliconFlow With the SiliconFlow integration configured and enabled in **AI Settings**, the following features become available: ### All Alarms Summary OpManager can consolidate all active alarms into a single, easy-to-read summary highlighting the most critical details across your monitored infrastructure. 1. Navigate to **Alarms** and select the **Summarize** tab in the top-right corner. OpManager will instantly generate the summary without any additional input. ![AI-generated summary of all active alarms on the Alarms page](https://cdn.manageengine.com/sites/meweb/images/network-monitoring/images/siliconflow_all_alarms_summary.png) ### Individual Alarm Summary OpManager's SiliconFlow integration can analyze individual alarms in detail, identifying the alarm type, listing probable causes, and generating a detailed, actionable summary for that specific alarm. 1. Navigate to **Alarms** and open any alarm of your choice, and select the **Summarize** tab to generate a detailed summary for that alarm. ![AI-generated summary of a single alarm showing alarm type and probable causes](https://cdn.manageengine.com/sites/meweb/images/network-monitoring/images/siliconflow_single_alarm_summary.png) ### Device Group Summary The SiliconFlow integration enables AI-generated summaries for device groups in OpManager, providing a consolidated snapshot of device conditions, key performance metrics, and actionable recommendations across all devices within the group. Group-level summaries are better suited for monitoring large network segments, offering a broader view that helps identify patterns and issues across multiple devices at once. 1. Go to **Settings → Configurations → Groups**. Device groups can also be accessed directly from **Inventory**. 2. Select a device group and click the **Summarize** tab to generate the AI-powered summary. ![Device group page with the Summarize tab](https://cdn.manageengine.com/sites/meweb/images/network-monitoring/images/siliconflow_grouppage.png) ![AI-generated device group summary showing device conditions, key metrics, and recommendations](https://cdn.manageengine.com/sites/meweb/images/network-monitoring/images/siliconflow_groupsummary.png) ### Device Summary OpManager's SiliconFlow integration can generate a focused summary for any individual device, covering its overall health status and key performance metrics in a single consolidated view. 1. Navigate to **Inventory** and select a device to open its snapshot page. 2. Click the **Summarize** tab within the snapshot page to trigger the AI-generated summary. ![Device snapshot page with the Summarize tab](https://cdn.manageengine.com/sites/meweb/images/network-monitoring/images/siliconflow_devicepage.png) ![AI-generated device summary showing health status and key performance metrics](https://cdn.manageengine.com/sites/meweb/images/network-monitoring/images/siliconflow_devicesummary.png) ### Problem Summary OpManager's SiliconFlow integration extends AI analysis to correlated **Problems**. When related alarms are grouped into a single Problem through [Event Correlation](https://www.manageengine.com/network-monitoring/problem-and-event-correlation.html), SiliconFlow analyzes the associated alarms and identifies the probable root cause, tagged with a high or medium confidence level, along with suggested remediation steps. 1. Navigate to **Alarms → Problems** and open the Problem you want to analyze. 2. Click **Analyze with AI** to generate the summary. ![AI-generated Problem summary showing probable root cause with confidence level and remediation steps](https://cdn.manageengine.com/sites/meweb/images/network-monitoring/images/siliconflow_problem_summary.png) ### Script Generation OpManager's [script monitoring](https://www.manageengine.com/network-monitoring/help/script-template.html) supports the execution of custom scripts (including PowerShell, Shell, VBScript, Perl, and Python) to monitor devices and capture script outputs as metrics. The SiliconFlow integration extends this capability by allowing script templates to be generated automatically using AI. Instead of writing scripts manually, a plain-language prompt can be entered and SiliconFlow will produce the required script instantly. 1. Go to **Settings → Monitoring → Script Templates**. 2. Click **Add** and fill in the required monitoring details. 3. Under the **Script Details** section, click **Generate with AI** to open the SiliconFlow prompt interface. ![Script Templates page with the Generate with AI button under Script Details](https://cdn.manageengine.com/sites/meweb/images/network-monitoring/images/siliconflow_script_template_page.png) ![SiliconFlow prompt window for describing the script to generate](https://cdn.manageengine.com/sites/meweb/images/network-monitoring/images/siliconflow_script_generation.png) 4. In the prompt window, enter a description of the script to be generated (for example: *PowerShell script that returns free space percentage on C: as a number*). 5. Click **Generate** for SiliconFlow to process the prompt and produce the script automatically. 6. Review the generated script and save it as a template to use for device monitoring. **Caution:** AI-generated scripts can contain errors or unintended commands. Always review the generated script, and test it on a non-production device, before saving it as a template and deploying it for monitoring. ### SNMP OIDs for Performance Monitors From OpManager version 12.9.120 onward, SiliconFlow can fetch relevant SNMP OIDs based on a plain-language description of the metric you want to monitor, eliminating the need to look up OIDs manually. 1. Navigate to **Settings → Monitoring → Performance Monitors** and open or create a [performance monitor](https://www.manageengine.com/network-monitoring/help/add-snmp-monitor.html). 2. Enter a description of the metric you want to capture (for example: *Interface input error rate on a Cisco Catalyst 9300*). 3. Click **Fetch OIDs with AI**. SiliconFlow will return the relevant OIDs automatically. ![Performance monitor page with the Fetch OIDs with AI option returning suggested SNMP OIDs](https://cdn.manageengine.com/sites/meweb/images/network-monitoring/images/siliconflow_performance_monitor_script_generation.png) **Caution:** AI-suggested OIDs can be incomplete or incorrect for a specific device model or firmware version. Verify each OID against the vendor's MIB before saving the monitor. The OpManager—SiliconFlow integration consolidates AI-powered summaries, real-time insights, automated script generation, and SNMP OID lookup into a unified workflow, significantly reducing the need for manual analysis and enabling faster, more informed decision-making across network operations.