| Standard / Professional | Upgrade the service using the UpdateManager.bat /.sh file and once the upgrade is completed start the service to continue monitoring. | - Stop both primary and secondary Failover service.
- Follow the steps provided under UpdateManager.bat /.sh file to upgrade the service.
- Then, start the secondary service once as master and stop the service.
- Now start the primary service followed by secondary service.
| - Stop both primary and secondary service
- Begin with upgrading the primary service using UpdateManager.bat /.sh file.
- Once primary service upgrade is successful, perform upgrade on secondary service using UpdateManager.bat /.sh file.
- After installing the ppm file, start the secondary service followed by the primary service.
- The secondary service will automatically switch to standby mode once primary service is started completely.
|
| Enterprise Edition | - Stop the Firewall Analyzer Central and all the Probe services.
- Upgrade using UpdateManager.bat /.sh file.
- Once the upgrade is completed, start the Central service.
- Then, the Probes will detect the upgrade, perform it in all the Probes and start the services on its own.
| - Stop both primary and secondary service in Firewall Analyzer Central.
- Stop the secondary service and ensure only the primary service in running in all Probes.
- Follow the steps provides under UpdateManager.bat /.sh file to perform upgrade in Central.
- Once upgrade is completed start the Firewall Analyzer Central service.
- Then, the Probes will detect the upgrade, perform automatically in all the Probe services.
- Start and stop the Standby service once as master across Central and Probe, then start the primary followed by the Standby service.
| - Download the appropriate version
- Stop all primary services and secondary service across Central and all Probes.
- Perform upgrade on Primary service and followed by secondary service in Central and all Probes using UpdateManager.bat /.sh file.
- Start the secondary service first, then followed by the Primary Service.
- The secondary will switch to standby mode automatically once primary service is started completely.
|