If your organization is expanding and looking to introduce additional elements and monitors, follow this guide on scalability recommendations. We've outlined the maximum counts and limits for resources and metrics in OpManager to maintain optimal performance. Use the OpManager System Requirements calculator and Disk Space calculator to get an accurate estimate of your system's required specifications.
Listed below are the maximum counts and limits for various elements and monitors in OpManager.
We recommend monitoring up to 10,000 interfaces in a single installation for the Standard/Professional Edition. For the Enterprise Editions from version 12.8.456, up to 15,000 interfaces can be monitored per probe.
If the count exceeds the recommended limit, it will be efficient to increase the monitoring interval of those interfaces. Adding more interfaces will directly impact the overall performance of the product.
Note:
Without carrying out load-related configuration changes or affecting the network performance, you can install and monitor up to 1,000 agent-based devices for hassle-free network monitoring.
OpManager restricts the number of elements per group to 2,000 to avoid any lapse in the performance of the product. Further elements cannot be added to the group if the limit is reached.
We recommend adding fewer than 500 elements in a business view for better visualization of devices in the MapView page.
OpManager can monitor a maximum of 2,500 access points at once. Regardless of the number of wireless LAN controllers in your inventory, the maximum cumulative number of associated access points that can be monitored is 2,500. In the Enterprise Edition, you can monitor a maximum of 2,500 access points per probe.
To avoid any hindrance in the performance of the product, OpManager limits the count of VLANs discovered to a maximum of 3,000. New VLANs will not be allowed to be discovered in OpManager past the specified limit.
To avoid any performance degradation in OpManager, the number of traps to be processed per hour is limited to a maximum of 50,000. If this threshold is breached, OpManager stops processing traps for a temporary period.
Based on the monitor type/protocol being used with the performance or availability monitor, the maximum advisable number of monitors for a single installation are given below.
Given below is the maximum advisable number of monitors for a single installation, when monitoring 1,000 devices.
| Protocol | Monitoring interval | Polls/min |
|---|---|---|
| Availability | 5 | 200 |
| SNMP & Interface | 15 | 1000 |
| WMI & Application Monitors | 15 | 300 |
| CLI | 15 | 150 |
| VMware | 10 | 1000 |
| Xen | 10 | 500 |
| Maximum load (per installation) | 10 | 1500 |
Given below is the maximum advisable number of monitors for a single probe, when monitoring up to 2,500 devices.
| Protocol | Monitoring interval | Polls/min |
|---|---|---|
| Availability | 5 | 500* |
| SNMP & Interface | 15 | 2000 |
| WMI & Application Monitors* | 15 | 1000* |
| CLI | 15 | 250 |
| VMware | 10 | 1000 |
| Xen | 10 | 500 |
| Maximum load (per installation) | 10 | 2500 |
A syslog rate of 200 syslogs per 2 minutes is recommended to avoid any hindrance in the product performance.
If the NetFlow processing limit exceeds 1,000 flows per second, it will affect OpManager's performance. Ensure the NetFlow processing limit is within the recommended rate.
Ensure the Firewall log processing limit is under 1,000 logs per second to avoid any lapse in the performance of the product.
OpManagerEnterprise Edition monitors multiple remote sites using OpManager Central and probe servers. The maximum number of devices monitored by OpManager Enterprise Edition, maximum number of probes supported, and related limits are listed below.
| Maximum number of devices monitored | 10,000 |
| Maximum number of interfaces monitored | 50,000 |
OpManager Enterprise Edition's Lite Central option helps you retain the archived data at probe level, helping you optimize performance by reducing the load on the Central server's database.
| Maximum number of devices monitored | 30,000 |
| Maximum number of interfaces monitored | 100,000 |
For OpManager Enterprise Edition's Lite Central option, a maximum of 100 probes will be supported.
Ensure that the latency between OpManager's Central server and a connected probe is within 50 ms (both ways). The Central server can still function at a higher latency, but when the latency crosses 100 ms, its performance can be affected.
The probes send alarm details to the Central server, which is capable of processing 1,000 alerts per minute at peak performance. Note that the Central server is capable of handling more than 1,000 alerts per minute, but this may have a slight impact on its performance.
If you need to monitor more than the mentioned scalability recommendations, please contact our support team at opmanager-support@manageengine.com.