OpManager Plus Performance Monitors

A list of all the performance monitors used in OpManager Plus along with the vendor details, description, protocol and category can be found in this list: 

VendorMonitorsDescriptionProtocolCategory
3ComCPU TemperatureMonitors the CPU temperatureSNMPSwitch / Wireless
3ComCPU UtilizationMonitors the CPU utilizationSNMPSwitch / Wireless
A10 NetworksActive ConnectionsMonitors the count of current connections.SNMPLoad Balancer/WAN Accelerator
A10 NetworksCPU UtilizationMonitors the average CPU usage in last 5 seconds.SNMPLoad Balancer/WAN Accelerator
A10 NetworksDisk UtilizationMonitors the usage of the disk in MB.SNMPLoad Balancer/WAN Accelerator
A10 NetworksFan StatusMonitors the fan status: 0: Failed, 4: OK-fixed/high, 5: OK-low/med, 6: OK-med/med, 7: OK-med/high, -2: not ready, 1: unknown.SNMPLoad Balancer/WAN Accelerator
A10 NetworksFree disk SpaceMonitors the Free space of the disk in MB.SNMPLoad Balancer/WAN Accelerator
A10 NetworksLower Power Supply StatusMonitors the lower power supply status. Power supply status : off(0),on(1),unknown(-1).SNMPLoad Balancer/WAN Accelerator
A10 NetworksMemory UtilizationMonitors the memory utilization(%).SNMPLoad Balancer/WAN Accelerator
A10 NetworksServer CountThe total count of axServer entries in the table.SNMPLoad Balancer/WAN Accelerator
A10 NetworksSystem TemperatureMonitors the physical system temperature in Celsius.SNMPLoad Balancer/WAN Accelerator
A10 NetworksUpper Power Supply StatusMonitors the Upper power supply status. Power Supply status: off(0),on(1),unknown(-1).SNMPLoad Balancer/WAN Accelerator
AlcatelChassis TemperatureMaximum one-minute chassis temperature over the last hour (percent)SNMPSwitch / Router
AlcatelCMM CPU TemperatureMaximum one-minute CMM CPU temperature over the last hour (percent)SNMPSwitch / Router
AlcatelDevice CPU UtilizationMaximum one-minute device-level CPU utilization over the last hour (percent)SNMPSwitch / Router
AlcatelDevice Memory UtilizationMaximum one-minute device-level memory utilization over the last hour (percent)SNMPSwitch / Router
AlcatelModule CPU UtilizationMaximum one-minute module-level CPU utilization over the last hour (percent)SNMPSwitch / Router
AlcatelModuler Memory UtilizationMaximum one-minute module-level memory utilization over the last hour (percent)SNMPSwitch / Router
AmarantenAmaranten-ConnectionsMonitors the Connections of Amaranten FirewallSNMPFirewall
AmarantenCPU UtilizationMonitors the CPU of Amaranten FirewallSNMPFirewall
AmarantenMemory UtilizationMonitors the Memory of Amaranten FirewallSNMPFirewall
American Power Conversion Corp.Number of PDU OutletsMonitors the OID will return the number of outlets contained in the device.SNMPUPS / PDU
American Power Conversion Corp.PDU Bank LoadMonitors the OID will return the phase/bank load measured in tenths of Amps.SNMPUPS / PDU
American Power Conversion Corp.PDU Phase LoadMonitors the current draw, in tenths of Amps, of the load on the Rack PDU phase being queriedSNMPUPS / PDU
American Power Conversion Corp.PDU Phase Load statusMonitors the present load status of the Rack PDU phase being queried { lowLoad ( 1 ) , normal ( 2 ) , nearOverload ( 3 ) , overload ( 4 ) }SNMPUPS / PDU
American Power Conversion Corp.PDU PhasesMonitors the OID will return the number of phases supported by the device.SNMPUPS / PDU
American Power Conversion Corp.PDU Power LoadMonitors the load power, in hundredths of kiloWatts, consumed on the Rack PDU phase being queriedSNMPUPS / PDU
American Power Conversion Corp.PDU VoltageMonitors the Voltage, in Volts, of the Rack PDU phase being queriedSNMPUPS / PDU
American Power Conversion Corp.UPS ChargeMonitors UPS ChargeSNMPUPS
American Power Conversion Corp.UPS Input Line VoltageThe current utility line voltage in VACSNMPUPS
American Power Conversion Corp.UPS LoadMonitors UPS LoadSNMPUPS
American Power Conversion Corp.UPS Output CurrentThe current in ampres drawn by the load on the UPSSNMPUPS
American Power Conversion Corp.UPS Output VoltageThe output voltage of the UPS system in VACSNMPUPS
APCCPU UtilizationCPU UtilizationSNMPUPS
APCTotal Active SessionsTotal Active SessionsSNMPUPS
ArrayConnectionMonitors the Connections of Array-APV LoadBalancerSNMPLoad Balancer
ArrayCPU UtilizationMonitors the CPU of Array-APV LoadBalancerSNMPLoad Balancer
ArrayMemory UtilizationMonitors the Memory of Array-APV LoadBalancerSNMPLoad Balancer
AutelanCPU UtilizationMonitors the CPU of Autelan-AS3200 SwitchSNMPSwitch
AutelanMemory UtilizationMonitors the Memory of Autelan-AS3200 SwitchSNMPSwitch
BarracudaBounced Mail QueuesMonitors the Bounced mail queuesSNMPNetworking Device
BarracudaBuffer MemoryMonitors the system Buffer Momory UtilizationSNMPNetworking Device
BarracudaCPU UtilizationMonitors the system 15 minutes cpu LoadSNMPNetworking Device
BarracudaCPU Utilization (Last 1 min)Monitors the system last 1 minute cpu loadSNMPNetworking Device
BarracudaCPU Utilization (Last 5 min)Monitors the system last 5 minutes cpu LoadSNMPNetworking Device
BarracudaInBound Mail QueuesMonitors the InBound mail queuesSNMPNetworking Device
BarracudaMail InputMonitors the system Mail Input countsSNMPNetworking Device
BarracudaMail OutputMonitors the systems Mail output countsSNMPNetworking Device
BarracudaMemory UtilizationMonitors the system MemoryUtilizationSNMPNetworking Device
BarracudaOutBound Mail QueuesMonitors the OutBound Mail queuesSNMPNetworking Device
BarracudaUsed Disk SpaceMonitors the systems used disk spaceSNMPNetworking Device
Blue Coat Systems, Inc.Client HTTP ErrorsMonitors the number of HTTP errors caused by client connections.SNMPWAN Accelerator
Blue Coat Systems, Inc.Client HTTP Hit(s)Monitors the number of HTTP hits that the proxy clients have produced.SNMPWAN Accelerator
Blue Coat Systems, Inc.Client HTTP In TrafficMonitors the number of kilobits recieved from the clients by the proxy.SNMPWAN Accelerator
Blue Coat Systems, Inc.Client HTTP Out TrafficMonitors the number of kilobits delivered to clients from the proxy.SNMPWAN Accelerator
Blue Coat Systems, Inc.Client HTTP Request(s)Monitors the number of HTTP requests recieved from clients.SNMPWAN Accelerator
Blue Coat Systems, Inc.CPU UtilizationMonitors the CPU of Bluecoat SwitchesSNMPWAN Accelerator
Blue Coat Systems, Inc.CPU UtilizationMonitors the Percent of resource in use.SNMPWAN Accelerator
Blue Coat Systems, Inc.Disk UtilizationMonitors the Percent of resource in use. When the resource is disk, it is the amount of disk used by the cache subsytem.SNMPWAN Accelerator
Blue Coat Systems, Inc.Memory UtilizationMonitors the Memory of Bluecoat SwitchesSNMPWAN Accelerator
Blue Coat Systems, Inc.Memory UtilizationMonitors the MemoryUtilization.SNMPWAN Accelerator
Blue Coat Systems, Inc.Objects In CacheMonitors the number of objects currently held by the proxy.SNMPWAN Accelerator
Blue Coat Systems, Inc.Server HTTP ErrorsMonitors the number of HTTP errors while fetching objects.SNMPWAN Accelerator
Blue Coat Systems, Inc.Server HTTP In TrafficMonitors the number of Kbs recieved by the proxy from remote servers.SNMPWAN Accelerator
Blue Coat Systems, Inc.Server HTTP Out TrafficMonitors the number of kbs transmitted by the proxy to remote servers.SNMPWAN Accelerator
Blue Coat Systems, Inc.Server HTTP RequestsMonitors the number of Http requests that the proxy has issued.SNMPWAN Accelerator
Check Point Software Technologies LtdFW Dropped PacketsMonitors the number of dropped packetsSNMPFirewall
Check Point Software Technologies LtdFW Logged PacketsMonitors the number of logged packetsSNMPFirewall
Check Point Software Technologies LtdFW Rejected PacketsMonitors the number of rejected packetsSNMPFirewall
CiscoAborted Interface In PacketsMonitors the aborted interfaces in packetsSNMPNetworking Device
CiscoActive Session CountActive Session CountSNMPFirewall
CiscoAssociated Mobile StationsMonitors the number of Mobile Stations currently associated with the WLAN.SNMPWireless
CiscoAssociated Mobile User(s)Monitors associated Mobile User(s) for Cisco devicesSNMPWireless
CiscoBackplane UtilizationMonitors the Backplane UtilizationSNMPSwitch
CiscoBGP PEER STATEidle2, connect3, active4, opensent5, openconfirm6, establishedSNMPRouter
CiscoBig Buffer HitsMonitors the Total big buffer hitsSNMPRouter
CiscoBig Buffer MissesMonitors the Total big buffer missesSNMPRouter
CiscoBuffer Create FailuresMonitors the buffer create failuresSNMPRouter
CiscoBuffer FailuresMonitors the Buffer FailuresSNMPRouter
CiscoCardOperstatus1 : not-specified2 : up3 : down4 : standbySNMPSwitch
CiscoChassis Input PowerMonitors the Chassis Input PowerUCSUCS
CiscoChassis Output PowerMonitors the Chassis Output PowerUCSUCS
CiscoCisco Memory UtilizationMonitors the Memory UtilizationSNMPNetworking Device
CiscoCisco TemperatureMonitors temperature at the testpoint maintained by the environmental monitorSNMPNetworking Device
CiscoCPU Usage (1 min avg)Monitors the one-minute moving average of the CPU busy percentageSNMPNetworking Device
CiscoCPU Usage (5 mins avg)Monitors the five-minute moving average of the CPU busy percentageSNMPNetworking Device
CiscoCPU Usage (5 secs avg)Monitors the CPU busy percentage in the last 5 secondsSNMPNetworking Device
CiscoCPU UtilizationMonitors the average utilization of CPU on the active supervisor.SNMPSwitch
CiscoCPU UtilizationMonitors the device CPU Utilization.SNMPNetworking Device
CiscoCPU Utilization(WLC)Monitors the Current CPU Load of the switch (Cisco WLC device) in percentage.SNMPWireless
CiscodevCellularstatusCustom MonitorSNMPWireless
CiscodevClientCountCustom MonitorSNMPWireless
CiscodevContactedatCustom MonitorSNMPWireless
CiscodevLanIPCustom MonitorSNMPWireless
CiscodevMacCustom MonitorSNMPWireless
CiscodevMeshstatusCustom MonitorSNMPWireless
CiscodevNameCustom MonitorSNMPWireless
CiscodevNetworknameCustom MonitorSNMPWireless
CiscodevProductcodeCustom MonitorSNMPWireless
CiscodevProductdescriptionCustom MonitorSNMPWireless
CiscodevpublicIPCustom MonitorSNMPWireless
CiscodevSerialCustom MonitorSNMPWireless
CiscodevStatuCustom MonitorSNMPWireless
CiscodevSubnetCustom MonitorSNMPWireless
CiscoDisk UtilizationMonitors the disk I/O utilization.SNMPFirewall
CiscoFabric Interconnect CPU UtilizationMonitors the Fabric Interconnect CPU UtilizationUCSUCS
CiscoFabric Interconnect FanCtrlrInlet1Monitors the Fabric Interconnect FanCtrlrInlet1UCSUCS
CiscoFabric Interconnect FanCtrlrInlet2Monitors the Fabric Interconnect FanCtrlrInlet2UCSUCS
CiscoFabric Interconnect FanCtrlrInlet3Monitors the Fabric Interconnect FanCtrlrInlet3UCSUCS
CiscoFabric Interconnect FanCtrlrInlet4Monitors the Fabric Interconnect FanCtrlrInlet4UCSUCS
CiscoFabric Interconnect MainBoardOutlet1Monitors the Fabric Interconnect MainBoardOutlet1UCSUCS
CiscoFabric Interconnect MainBoardOutlet2Monitors the Fabric Interconnect MainBoardOutlet2UCSUCS
CiscoFabric Interconnect MemAvailableMonitors the Fabric Interconnect Memory AvailableUCSUCS
CiscoFabric Interconnect MemCachedMonitors the Fabric Interconnect MemCachedUCSUCS
CiscoFabric Interconnect PsuCtrlrInlet1Monitors the Fabric Interconnect PsuCtrlrInlet1UCSUCS
CiscoFabric Interconnect PsuCtrlrInlet2Monitors the Fabric Interconnect PsuCtrlrInlet2UCSUCS
CiscoFan SpeedMonitors the Fan SpeedUCSUCS
CiscoFanModule Exhaust TemperatureMonitors the FanModule Exhaust TemperatureUCSUCS
CiscoFirewall CPU UtilizationMonitors the CPU utilization of the FirewallSNMPFirewall
CiscoFree 1550K BuffersMonitors the number of free 1550K blocksSNMPNetworking Device
CiscoFree 256K BuffersMonitors the number of free 256K blocksSNMPNetworking Device
CiscoFree 4K BuffersMonitors the number of free 4K blocksSNMPNetworking Device
CiscoFree 80K BuffersMonitors the number of free 80K blocksSNMPNetworking Device
CiscoFree MemoryMonitors the number of bytes from the memory pool that are currently unusedSNMPNetworking Device
CiscoIgnored Interface In PacketsMonitors the ignored interfaces in packetsSNMPNetworking Device
CiscoInput Packet DropsMonitors the input packets drops after the input queue was fullSNMPNetworking Device
CiscoInterface CollisionsMonitors the interface collisionsSNMPNetworking Device
CiscoInterface In CRC ErrorsMonitors the number of input packets which had cyclic redundancy checksum errorsSNMPNetworking Device
CiscoInterface In GiantsMonitors the number of input packets larger than the physical media permittedSNMPNetworking Device
CiscoInterface In RuntsMonitors the interface in runtsSNMPNetworking Device
CiscoInterface Input BitsMonitors the five-minute exponentially decayed moving average of input bits per secondSNMPNetworking Device
CiscoInterface Output BitsMonitors the five-minute exponentially decayed moving average of output bits per secondSNMPNetworking Device
CiscoInterface Reset CountMonitors the number of times the interface has internally resetSNMPNetworking Device
CiscoInterface Restart CountMonitors the number of times the interface needed to be completely restartedSNMPNetworking Device
CiscoIronport TemperatureMonitors the Temperature in degrees Celsius.SNMPFirewall
CiscoLargest Free MemoryMonitors the largest number of contiguous bytes from the memory pool that are currently unusedSNMPNetworking Device
CiscoMailTransfer ThreadsMonitors the number of threads that perform some task related to transferring mail.SNMPFirewall
CiscoMedium Buffer HitsMonitors the Total medium buffer hitsSNMPRouter
CiscoMedium Buffer MissesMonitors the Total medium buffer missesSNMPRouter
CiscoMemory UtilizationMonitors the average utilization of memory on the active supervisor.SNMPSwitch
CiscoMemory UtilizationMonitors the device memory utilization.SNMPFirewall
CiscoMemory UtilizationMonitors the device Memory UtilizationSNMPSwitch
CiscoMemory Utilization(WLC)Monitors the current Memory Utilization of the Cisco WLC device.SNMPWireless
CiscoModems in UseCustom MonitorSNMPRouter
CiscoMotherboard Consumed PowerMonitors the Monitors the Motherboard Consumed PowerUCSUCS
CiscoMotherboard Input CurrentMonitors the Motherboard Input CurrentUCSUCS
CiscoMotherboard Input VoltageMonitors the Motherboard Input VoltageUCSUCS
CiscoOpenFilesOrSocketsMonitors the number of open files or sockets.SNMPFirewall
CiscoOSPF IF Statedown2, loopback3, waiting4, pointToPoint5, designatedRouter6, backupDesignatedRouter7, otherDesignatedRouterSNMPRouter
CiscoOutput Packet DropsMonitors the output packets dropSNMPRouter
CiscoOutstanding DNS RequestsMonitors the number of DNS requests that have been sent but for which no reply has been received.SNMPFirewall
CiscoPending DNS RequestsMonitors the number of DNS requests waiting to be sent.SNMPFirewall
CiscoPSUs Input VoltageMonitors the PSUs Input VoltageUCSUCS
CiscoPSUs Internal TemperatureMonitors the PSUs Internal TemperatureUCSUCS
CiscoPSUs Output CurrentMonitors the PSUs Output CurrentUCSUCS
CiscoPSUs Output PowerMonitors the PSUs Output PowerUCSUCS
CiscoPSUs Output12vMonitors the PSUs Output12vUCSUCS
CiscoPSUs Output3v3Monitors the PSUs Output3v3UCSUCS
CiscoRouter Memory UtilizationMonitors the Memory utilization of the routerSNMPRouter
CiscoSmall Buffer HitsMonitors the Total small buffer hitsSNMPNetworking Device
CiscoSmall Buffer MissesMonitors the Total small buffer missesSNMPRouter
CiscoSwitch CPU Utilization(5 mins avg)Monitors the five-minute moving average of the CPU busy percentageSNMPSwitch
CiscoSwitch Memory UtilizationMonitors the Memory utilization of the switchSNMPNetworking Device
CiscosysUpTimeAtLastChassisChange"Time in seconds/100 from the last coldstart to the last change in the chassis configuration. This value will be updatedwhenever the chassis experiences a changein the count, type, or slot position ofa card in cardTable."SNMPSwitch
CiscoTemperature(WLC)Monitors the current Internal Temperature of the unit in Centigrade(Cisco WLC).SNMPWireless
CiscoTotal Huge Buffer HitsMonitors the huge buffer hitsSNMPRouter
CiscoTotal Huge Buffer MissesMonitors the total huge buffer missesSNMPRouter
CiscoTotal Large Buffer HitsMonitors the Total large buffer hitsSNMPRouter
CiscoTotal Large Buffer MissesMonitors the total large buffer missesSNMPRouter
CiscoTunnel In-Drop PacketsVPN Tunnel In-Drop PacketsSNMPFirewall
CiscoTunnel In-OctetVPN Tunnel In-OctetSNMPFirewall
CiscoTunnel In-PacketsVPN Tunnel In-PacketsSNMPFirewall
CiscoTunnel Out-Drop PacketsVPN Tunnel Out-Drop PacketsSNMPFirewall
CiscoTunnel Out-OctetVPN Tunnel Out-OctetSNMPFirewall
CiscoTunnel Out-PacketsVPN Tunnel Out-PacketsSNMPFirewall
CiscoUsed MemoryMonitors the number of bytes from the memory pool that are currently in useSNMPNetworking Device
Citrix Systems, Inc.Active Server Connection(s)Monitors the number of connections currently serving requests.SNMPLoad Balancer
Citrix Systems, Inc.Client Connection(s) in ClosingStateMonitors the number of client connections in NetScaler in closing states.SNMPLoad Balancer
Citrix Systems, Inc.Client Connection(s) in OpeningStateMonitors the number of client connections in NetScaler in opening states.SNMPLoad Balancer
Citrix Systems, Inc.CPU UtilizationMonitors the CPU utilization percentage.SNMPLoad Balancer
Citrix Systems, Inc.CPU UtilizationAverage physical cpu usageXenServiceServer
Citrix Systems, Inc.CPU UtilizationAverage of VM VCPUs UtilizationXenServiceServer
Citrix Systems, Inc.Current Client Connection(s)Monitors the number of client connections in NetScaler.SNMPLoad Balancer
Citrix Systems, Inc.Current Server Connection(s)Monitors the number of server connections in NetScaler.SNMPLoad Balancer
Citrix Systems, Inc.Disk I/O UsageVirtual Disk I/O Usage of VMXenServiceServer
Citrix Systems, Inc.Disk UtilizationMonitors the Percentage of the disk space used.SNMPLoad Balancer
Citrix Systems, Inc.Domain0 Average LoadLoad for Domain0 in XenServerXenServiceServer
Citrix Systems, Inc.Established Client Connection(s)Monitors the number of client connections in NetScaler in established state.SNMPLoad Balancer
Citrix Systems, Inc.Established Server Connection(s)Monitors the number of server connections in NetScaler in established state.SNMPLoad Balancer
Citrix Systems, Inc.Http Total GetsMonitors the number of HTTP GET requests received.SNMPLoad Balancer
Citrix Systems, Inc.Http Total Others(non-GET/POST)Monitors the number of non-GET/POST HTTP methods received.SNMPLoad Balancer
Citrix Systems, Inc.Http Total PostsMonitors the number of HTTP POST requests received.SNMPLoad Balancer
Citrix Systems, Inc.Memory Allocation By XAPIMemory allocation done by the xapi daemonXenServiceServer
Citrix Systems, Inc.Memory UtilizationMonitors the Memory utilization percentage.SNMPLoad Balancer
Citrix Systems, Inc.Memory UtilizationMemory Utilization of hostXenServiceServer
Citrix Systems, Inc.Memory UtilizationMemory Utilization of VMXenServiceServer
Citrix Systems, Inc.Network Received RateBytes per second received on all physical interfacesXenServiceServer
Citrix Systems, Inc.Network Transmitted RateBytes per second sent on all physical interfacesXenServiceServer
Citrix Systems, Inc.Network UsageNetwork Usage of hostXenServiceServer
Citrix Systems, Inc.Network UsageNetwork I/O Usage by XenServer VMXenServiceServer
Citrix Systems, Inc.scPolicy Url HitsThis counter gives the number of times netscaler matched an incoming request with a Configured sureconnect policy.SNMPLoad Balancer
Citrix Systems, Inc.scSession RequestsThis counter gives the number of requests which came in a SureConnect session.SNMPLoad Balancer
Citrix Systems, Inc.SSL CardsUPMonitors the number of ssl cards UP. If number of cards UP is lower than a threshold, a failover will be initiated.SNMPLoad Balancer
Citrix Systems, Inc.SSL session(s)Monitors the number of SSL sessions.SNMPLoad Balancer
Citrix Systems, Inc.TCP Total ClientConnection OpenedMonitors the total number of opened client connections.SNMPLoad Balancer
Citrix Systems, Inc.TCP TotalSynMonitors the number of SYN packets received.SNMPLoad Balancer
Citrix Systems, Inc.TCPSurgeQueueLengthMonitors the number of connections in surge queue.SNMPLoad Balancer
Citrix Systems, Inc.Total Hit(s)Monitors the total hits for the policy.SNMPLoad Balancer
Citrix Systems, Inc.Total Policy HitsMonitors the Total policy hits count.SNMPLoad Balancer
Citrix Systems, Inc.TTFB between Netscaler to serverMonitors the average TTFB between the netscaler and the server.SNMPLoad Balancer
Citrix Systems, Inc.VCPUs Concurrency HazardFraction of time that some VCPUs are running and some are runnableXenServiceServer
Citrix Systems, Inc.VCPUs Full ContentionFraction of time that all VCPUs are runnable (i.e., waiting for CPU)XenServiceServer
Citrix Systems, Inc.VCPUs Full RunFraction of time that all VCPUs are runningXenServiceServer
Citrix Systems, Inc.VCPUs IdleFraction of time that all VCPUs are blocked or offlineXenServiceServer
Citrix Systems, Inc.VCPUs Partial ContentionFraction of time that some VCPUs are runnable and some are blockedXenServiceServer
Citrix Systems, Inc.VCPUs Partial RunFraction of time that some VCPUs are running, and some are blockedXenServiceServer
Citrix Systems, Inc.VServer Current ClientConnectionsMonitors the number of current client connections.SNMPLoad Balancer
Citrix Systems, Inc.VServer Current OutOfService(s)Monitors the current number of services which are bound to this vserver and are in the state 'outOfService'.SNMPLoad Balancer
Citrix Systems, Inc.VServer Current ServerConnectionsMonitors the number of current connections to the real servers behind the vserver.SNMPLoad Balancer
Citrix Systems, Inc.VServer Current ServicesDownMonitors the current number of services which are bound to this vserver and are in the state 'down'.SNMPLoad Balancer
Citrix Systems, Inc.VServer Current ServicesUpMonitors the current number of services which are bound to this vserver and are in the state 'up'.SNMPLoad Balancer
Citrix Systems, Inc.VServer Total HitsMonitors the Total vserver hits.SNMPLoad Balancer
Citrix Systems, Inc.VServer Total RequestBytesMonitors the total number of request bytes received on this service/vserver.SNMPLoad Balancer
Citrix Systems, Inc.VServer Total RequestsMonitors the total number of requests received on this service/vserver(This is applicable for HTTP/SSL servicetype).SNMPLoad Balancer
Citrix Systems, Inc.VServer Total ResponseBytesMonitors the number of response bytes received on this service/vserver.SNMPLoad Balancer
MGEUPS ChargeMonitors UPS ChargeSNMPUPS
Citrix Systems, Inc.VServer TotalResponsesMonitors the number of responses received on this service/vserver(This is applicable for HTTP/SSL servicetype).SNMPLoad Balancer
Citrix Systems, Inc.XAPI Memory UsageXenAPI Memory UtilizationXenServiceServer
CompaqCpqHe Server TemperatureMonitors the server tempratureSNMPServer
CompaqCPU UtilizationMonitors the CPU UtilizationSNMPServer
CompaqCPU Utilization (30 Min Avg)Monitors the CPU UtilizationSNMPServer
CompaqCPU Utilization (5 Min Avg)Monitors the CPU UtilizationSNMPServer
CompaqCPU Utilization (Hr. Avg)Monitors the CPU UtilizationSNMPServer
CompaqDeferred TransmissionMonitors the interfaces deffered transmissionSNMPServer
CompaqExcessive CollisionsMonitors the interface excessive collisionsSNMPServer
CompaqFile System Usage PercentageMonitors the percetage space used in File SystemSNMPServer
CompaqFile System Usage SizeMonitors the space used by file systemSNMPServer
CompaqFree Physical MemoryMonitors the free physical memorySNMPServer
CompaqFree Virtual MemoryMonitors the free virtual memorySNMPServer
CompaqInput VoltageMonitors the input voltage of power supplySNMPServer
CompaqInterface Rx ErrorsMonitors the interface receive errorsSNMPServer
CompaqInterface Rx TrafficMonitors the interface received trafficSNMPServer
CompaqInterface Tx ErrorsMonitors the interface transmit errorSNMPServer
CompaqInterface Tx TrafficInterface Transmit TrafficSNMPServer
CompaqInternal MAC Transmit ErrorsMonitors the internal MAC transmit errorsSNMPServer
CompaqLate CollisionsMonitors the interface Late CollisionsSNMPServer
CompaqMultiple Collision PacketsMultiple Collision FramesSNMPServer
CompaqPower CapacityMonitors the utilized power in WattsSNMPServer
CompaqSCSI Corrected Read ErrorsMonitors the SCSI corrected read errorsSNMPServer
CompaqSCSI Drive Spin Up TimeMonitors the SCSI drive spin up timeSNMPServer
CompaqSCSI Hard Read ErrorsMonitors the SCSI hard read errorsSNMPServer
CompaqSCSI Hard Write ErrorsMonitors the hard write errorsSNMPServer
CompaqSCSI High Read SectorsMonitors the SCSI high speed sectorSNMPServer
CompaqSCSI High Write SectorsMonitors the SCSI high write sectorsSNMPServer
CompaqSCSI Low Read SectorsMonitors the SCSI low read sectorSNMPServer
CompaqSCSI Low Write SectorsMonitors the SCSI low write sectorsSNMPServer
CompaqSCSI Recovered Read ErrorsMonitors the SCSI recovered read errorsSNMPServer
CompaqSCSI Recovered Write ErrorsMonitors the SCSI recovered write errorsSNMPServer
CompaqSCSI Seek ErrorsMonitors the SCSI seek errorsSNMPServer
CompaqSCSI Service TimeMonitors the SCSI service timeSNMPServer
CompaqSCSI Timeout ErrorsMonitors the SCSI timeout errorsSNMPServer
CompaqSCSI Trap PacketsMonitors the number of SCSI trap packetsSNMPServer
CompaqSCSI Used Reallocation SectorsMonitors the SCSI used reallocation sectorsSNMPServer
CompaqSingle Collision PacketsSingle Collision packetsSNMPServer
CompaqSNMP Trap Log SizeMonitors the SNMP trap log sizeSNMPServer
CompaqTraffic Trap CountMonitors the number of trap count in trafficSNMPServer
CyberoamCPU UtilizationMonitors the cpu usage.SNMPFirewall
CyberoamDisk UtilizationMonitors the used disk percentage.SNMPFirewall
CyberoamFTP HitsMonitors the count of Ftp Hits.SNMPFirewall
CyberoamHTTP HitsMonitors the count of Http Hits.SNMPFirewall
CyberoamIMAP HitsMonitors the count of imapHits.SNMPFirewall
CyberoamLive UsersMonitors the count of Live Users.SNMPFirewall
CyberoamMemory UtilizationMonitors the Momory utilization.SNMPFirewall
CyberoamPOP3 HitsMonitors the count of pop3Hits.SNMPFirewall
CyberoamSMTP HitsMonitors the count of Smtp Hit.SNMPFirewall
DCNCPU UtilizationCPU Utilization for DCNSNMPSwitch
DCNMemory UtilizationMemory Utilization for DCNSNMPSwitch
Dell Inc.AlertCustom MonitorSNMPNetworking Device
Dell Inc.CPU UtilizationCPU Utilization for DELL IncSNMPSwitch
Dell Inc.CPU UtilizationMonitors the CPU of DELL_Force10_S25N switchSNMPSwitch
Dell Inc.Memory UtilizationMonitors the Memory of DELL_Force10_S25N switchSNMPSwitch
Dell Inc.Memory UtilizationMemory Utilization for Dell IncSNMPSwitch
DPtechConnectionsMonitors the Connections of DPtech FirewallSNMPFirewall
DPtechCPU UtilizationCPU Utilization for DPtechSNMPFirewall
DPtechCPU UtilizationMonitor the CPU Utilization for DPtech devicesSNMPFirewall / Router
DPtechMemory UtilizationMemory Utilization for DPtechSNMPFirewall
DPtechMemory UtilizationMonitors the Memory of DPTECH SwitchesSNMPFirewall
DPtechMemory UtilizationMonitor the Memory Utilization for DPtech devicesSNMPFirewall / Router
EatonOnlineCustom MonitorSNMPUPS
EatonUPS Battery CurrentBattery Current as reported by the UPS metering. Current is positive when discharging, negative when recharging the battery.SNMPUPS
EatonUPS ChargeBattery percent charge.SNMPUPS
EatonUPS Input Line VoltageThe measured input voltage from the UPS meters in volts.SNMPUPS
EatonUPS Input SourceThe present external source of input power.SNMPUPS
EatonUPS LoadPowerware UPS LoadSNMPUPS
EatonUPS Output CurrentThe measured UPS output current in amps.SNMPUPS
EatonUPS Output VoltageThe measured output voltage from the UPS metering in volts.SNMPUPS
EatonUPS Time RemainingBattery run time in seconds before UPS turns off due to low battery.SNMPUPS
EmersonLiebertUPS ChargeMonitors UPS ChargeSNMPUPS
EmersonLiebertUPS LoadMonitors UPS LoadSNMPUPS
ExtremeExtreme CPU UtilizationMonitors the CPU Utilization for Extreme DevicesSNMPSwitch
ExtremeExtreme TemperatureMonitors the Temperature for Extreme DevicesSNMPSwitch
ExtremeXOS CPU UtilizationMonitors the XOS CPU Utilization for Extreme DevicesSNMPSwitch
ExtremeXOS Memory UtilizationMonitors the XOS Memory Utilization for Extreme DevicesSNMPSwitch
F5 Networks, Inc.Active Client Connection(s)Monitors F5 LoadBalancer Client Active Connections.SNMPLoad Balancer
F5 Networks, Inc.Active connections(server-PoolMember)Monitors the current connections from server-side to the pool member.SNMPLoad Balancer
F5 Networks, Inc.Active connections(ServerToSystem)Monitors the current connections from server-side to the system.SNMPLoad Balancer
F5 Networks, Inc.ActiveClientConnectionsMonitors the ActiveClientConnections of F5-BIG-IP-1600 LoadBalancerSNMPLoad Balancer
F5 Networks, Inc.ClusterMember StateMonitors the state indicating whether the specified member is enabled or not {false(0), true(1)}.SNMPLoad Balancer
F5 Networks, Inc.CPU FanSpeedMonitors the fan speed (in RPM) of the indexed CPU on the system., This is only supported for the platform where the sensor data is available.SNMPLoad Balancer
F5 Networks, Inc.CPU TemperatureMonitors the temperature of the indexed CPU on the system. This is only supported for the platform where the sensor data is available.SNMPLoad Balancer
F5 Networks, Inc.CPU UtilizationMonitors the CPU of F5-BIG-IP-1600 LoadBalancerSNMPLoad Balancer
F5 Networks, Inc.CPU UtilizationMonitors the CPU of F5 LoadBalancerSNMPLoad Balancer
F5 Networks, Inc.CPU UtilizationMonitors F5 LoadBalancer CPUUtilization.SNMPLoad Balancer
F5 Networks, Inc.Dropped Packet(s)Monitors the total dropped packets.SNMPLoad Balancer
F5 Networks, Inc.Global TM PoolMember StateMonitors the state indicating whether the specified pool member is enabled or not {disable(0), enable(1)}.SNMPLoad Balancer
F5 Networks, Inc.Global TM VirtualServer StatusMonitors the activity status of the specified virtual server, as specified by the user {none(0), enabled(1), disabled(2), disabledbyparent(3)}.SNMPLoad Balancer
F5 Networks, Inc.HTTP Request(s)Monitors the total number of HTTP requests to the LoadBalancer system.SNMPLoad Balancer
F5 Networks, Inc.Incoming Packet Error(s)Monitors the total incoming packet errors for the system.SNMPLoad Balancer
F5 Networks, Inc.Local TM PoolMember stateMonitors the activity status of the specified pool, as specified by the user{none(0), enabled(1), disabled(2), disabledbyparent(3)}.SNMPLoad Balancer
F5 Networks, Inc.Memory UtilizationMonitors the Memory of F5-BIG-IP-1600 LoadBalancerSNMPLoad Balancer
F5 Networks, Inc.Memory UtilizationMonitors the Memory of F5 LoadBalancerSNMPLoad Balancer
F5 Networks, Inc.Memory UtilizationMonitors F5 LoadBalancer MemoryUtilization.SNMPLoad Balancer
F5 Networks, Inc.Outgoing Packet Error(s)Monitors the total outgoing packet errors for the system.SNMPLoad Balancer
FiberHomeCPU UtilizationMonitors the CPU of FiberHome-EPON-5516 SwitchSNMPSwitch
FiberHomeCPU UtilizationMonitors the CPU of FiberHome-S2200ME-PAF SwitchSNMPSwitch
FiberHomeMemory UtilizationMonitors the Memory of FiberHome-EPON-5516 SwitchSNMPSwitch
FiberHomeMemory UtilizationMonitors the Memory of FiberHome-S2200ME-PAF SwitchSNMPSwitch
FortigateConnectionsMonitors the Connections of Fortigate Firewall 200BSNMPFirewall
FortigateConnectionsMonitors the Connections of Fortigate devicesSNMPRouter
FortigateCPU UtilizationMonitors the CPU of Fortigate Firewall 200BSNMPFirewall
FortigateCPU UtilizationMonitors the CPU of Fortigate devicesSNMPRouter
FortigateMemory UtilizationMonitors the Memory of Fortigate Firewall 200BSNMPFirewall
FortigateMemory UtilizationMonitors the Memory of Fortigate devicesSNMPRouter
Fortinet, Inc.Active Session CountActive Session CountSNMPRouter
Fortinet, Inc.CPU UtilizationMonitors the CPU utilizationSNMPFirewall
Fortinet, Inc.Memory UtilizationMonitors the Memory UtilizationSNMPFirewall
Foundry Networks, Inc.CPU UtilizationThe statistics collection of utilization of the CPU in the deviceSNMPSwitch
Foundry Networks, Inc.Foundry TemperatureTemperature of the chassis. Each unit is 0.5 degrees Celcius. Only management module built with temperature sensor hardware is applicable. For those non-applicable management module, it returns no-such-nameSNMPSwitch
Foundry Networks, Inc.PowerSupplyThe power supply operation statusSNMPSwitch
Foundry Networks, Inc.QosProfileCalculatedBandwidthQos Profile Calculated BandwidthSNMPSwitch
Foundry Networks, Inc.QosProfileRequestedBandwidthQos Profile Requested BandwidthSNMPSwitch
Foundry Networks, Inc.ViolatorPortNumberThe port number of the switch or router that received a violator packet. It is included in the locked address violation trapSNMPSwitch
H3CCPU UtilizationMonitors the CPU of H3C-S10508 SwitchSNMPSwitch
H3CCPU UtilizationMonitor the CPU Utilization for H3C devicesSNMPSwitch
H3CCPU UtilizationMonitors the CPU of H3C-S2108-E0004 switchSNMPSwitch
H3CCPU UtilizationMonitors the CPU of H3C-S3610-PWR-EI SwitchSNMPSwitch
H3CCPU UtilizationMonitors the CPU of H3C-S5120-52SC-HI SwitchSNMPSwitch
H3CCPU UtilizationCPU Utilization for H3CSNMPSwitch
H3CCPU UtilizationCPU Utilization for H3CSNMPSwitch
H3CCPU UtilizationMonitor the CPU Utilization for H3C devicesSNMPSwitch
H3CCPU UtilizationMonitors the CPU of H3C-S5800-32C SwitchSNMPSwitch
H3CCPU UtilizationMonitor the CPU Utilization for H3C devicesSNMPSwitch
H3CCPU UtilizationMonitor the CPU Utilization for H3C devicesSNMPSwitch
H3CCPU UtilizationMonitor the CPU Utilization for H3C devicesSNMPSwitch
H3CCPU UtilizationMonitors the CPU of H3C-S7506E-S SwitchesSNMPSwitch
H3CCPU UtilizationMonitor the CPU Utilization for H3C devicesSNMPSwitch
H3CCPU UtilizationMonitors the CPU of H3C-S9505E SwitchSNMPSwitch
H3CCPU UtilizationMonitor the CPU Utilization for H3C devicesSNMPSwitch
H3CCPU UtilizationMonitor the CPU Utilization for H3C devicesSNMPSwitch
H3CCPU UtilizationCPU Utilization for H3CSNMPFirewall
H3CCPU UtilizationMonitors the CPU of H3C-WX3008 SwitchesSNMPSwitch
H3CCPU UtilizationMonitors the CPU of H3C DevicesSNMPNetworking Device
H3CCPU UtilizationMonitor the CPU Utilization for H3C devicesSNMPSwitch
H3CCPU UtilizationMonitor the CPU Utilization for H3C devicesSNMPSwitch
H3CCPU UtilizationMonitor the CPU Utilization for H3C devicesSNMPRouter
H3CCPU UtilizationMonitor the CPU Utilization for H3C devicesSNMPNetworking Device
H3CCPU UtilizationMonitor the CPU Utilization for H3C devicesSNMPSwitch
H3CCPU UtilizationMonitor the CPU Utilization for H3C devicesSNMPSwitch
H3CCPU UtilizationMonitor the CPU Utilization for H3C devicesSNMPSwitch
H3CCPU UtilizationMonitor the CPU Utilization for H3C devicesSNMPSwitch
H3CCPU UtilizationMonitor the CPU Utilization for H3C devicesSNMPSwitch
H3CCPU UtilizationMonitor the CPU Utilization for H3C devicesSNMPSwitch
H3CCPU UtilizationMonitor the CPU Utilization for H3C devicesSNMPRouter / Firewall
H3CMemory UtilizationMonitors the Memory of H3C-S10508 SwitchSNMPSwitch
H3CMemory UtilizationMonitor the Memory Utilization for H3C devicesSNMPSwitch
H3CMemory UtilizationMonitors the Memory of H3C-S3610-PWR-EI SwitchSNMPSwitch
H3CMemory UtilizationMonitors the Memory of H3C-S5120-52SC-HI SwitchSNMPSwitch
H3CMemory UtilizationMemory Utilization for H3CSNMPSwitch
H3CMemory UtilizationMemory Utilization for H3CSNMPSwitch
H3CMemory UtilizationMonitor the Memory Utilization for H3C devicesSNMPSwitch
H3CMemory UtilizationMonitors the Memory of H3C-S5800-32C SwitchSNMPSwitch
H3CMemory UtilizationMonitor the Memory Utilization for H3C devicesSNMPSwitch
H3CMemory UtilizationMonitor the Memory Utilization for H3C devicesSNMPSwitch
H3CMemory UtilizationMonitor the Memory Utilization for H3C devicesSNMPSwitch
H3CMemory UtilizationMonitors the Memory of H3C-S7506E-S SwitchesSNMPSwitch
H3CMemory UtilizationMonitor the Memory Utilization for H3C devicesSNMPSwitch
H3CMemory UtilizationMonitors the Memory of H3C-S9505E SwitchSNMPSwitch
H3CMemory UtilizationMonitor the Memory Utilization for H3C devicesSNMPSwitch
H3CMemory UtilizationMonitor the Memory Utilization for H3C devicesSNMPSwitch
H3CMemory UtilizationMemory Utilization for H3CSNMPFirewall
H3CMemory UtilizationMonitors the Memory of H3C-WX3008 SwitchesSNMPSwitch
H3CMemory UtilizationMonitors the Memory of H3C DevicesSNMPNetworking Device
H3CMemory UtilizationMonitor the Memory Utilization for H3C devicesSNMPSwitch
H3CMemory UtilizationMonitor the Memory Utilization for H3C devicesSNMPSwitch
H3CMemory UtilizationMonitor the Memory Utilization for H3C devicesSNMPRouter
H3CMemory UtilizationMonitor the Memory Utilization for H3C devicesSNMPNetworking Device
H3CMemory UtilizationMonitor the Memory Utilization for H3C devicesSNMPSwitch
H3CMemory UtilizationMonitor the Memory Utilization for H3C devicesSNMPSwitch
H3CMemory UtilizationMonitor the Memory Utilization for H3C devicesSNMPSwitch
H3CMemory UtilizationMonitor the Memory Utilization for H3C devicesSNMPSwitch
H3CMemory UtilizationMonitor the Memory Utilization for H3C devicesSNMPSwitch
H3CMemory UtilizationMonitor the Memory Utilization for H3C devicesSNMPSwitch
H3CMemory UtilizationMonitor the Memory Utilization of H3C devicesSNMPSwitch
H3CMemory UtilizationMonitor the Memory Utilization for H3C devicesSNMPRouter / Firewall
Hewlett-PackardAssociated Mobile User(s)Monitors associated Mobile User(s) for HP devicesSNMPWireless
Hewlett-PackardCPU UtilizationMonitors the CPU Utilization for HP ProCurve DevicesSNMPSwitch
Hewlett-PackardMemory UtilizationMonitors the Memory Utilization for HP ProCurve DevicesSNMPSwitch
HillstoneActiveClientConnectionsMonitors the ActiveClientConnections of Hillstone-SG-6000-G5150 FirewallSNMPFirewall
HillstoneCPU UtilizationMonitors the CPU of Hillstone-SG-6000-G5150 FirewallSNMPFirewall
HillstoneMemory UtilizationMonitors the Memory of Hillstone-SG-6000-G5150 FirewallSNMPFirewall
HuaweiCPU UtilizationMonitors the CPU of Eudemon1000E FirewallSNMPFirewall
HuaweiCPU UtilizationMonitors the CPU of Huawei-Symantec-USG9310 RouterSNMPRouter
HuaweiCPU UtilizationMonitors the CPU of Huawei-AR1220 RoutersSNMPRouter
HuaweiCPU UtilizationMonitors the CPU of Huawei-AR2240 RoutersSNMPRouter
HuaweiCPU UtilizationMonitors the CPU of Huawei DevicesSNMPSwitch
HuaweiCPU UtilizationMonitors the CPU of Huawei-epon-MA5600T SwitchSNMPSwitch
HuaweiCPU UtilizationMonitors the CPU of Huawei-epon-olt SwitchSNMPSwitch
HuaweiCPU UtilizationCPU Utilization for HuaweiSNMPFirewall
HuaweiCPU UtilizationMonitors the CPU of Huawei NE20E RouterSNMPRouter
HuaweiCPU UtilizationMonitors the CPU of Huawei-NE40-4 RouterSNMPRouter
HuaweiCPU UtilizationMonitors the CPU of Huawei-Quidway-Router-R2621 RouterSNMPRouter
HuaweiCPU UtilizationCPU Utilization for HuaweiSNMPSwitch
HuaweiCPU UtilizationCPU Utilization for HuaweiSNMPSwitch
HuaweiCPU UtilizationMonitors the CPU of Huawei devicesSNMPSwitch
HuaweiCPU UtilizationMonitor the CPU Utilization for Huawei devicesSNMPSwitch
HuaweiCPU UtilizationMonitors the CPU of Huawei S3352 SwitchesSNMPSwitch
HuaweiCPU UtilizationCPU Utilization for HuaweiSNMPSwitch
HuaweiCPU UtilizationCPU Utilization for HuaweiSNMPSwitch
HuaweiCPU UtilizationCPU Utilization for HuaweiSNMPSwitch
HuaweiCPU UtilizationMonitors the CPU of Huawei-S7703 switchSNMPSwitch
HuaweiCPU UtilizationCPU Utilization for HuaweiSNMPSwitch
HuaweiCPU UtilizationMonitor the CPU Utilization for Huawei devicesSNMPSwitch / Router
HuaweiCPU UtilizationMonitors the CPU of Huawei S9303 SwitchesSNMPSwitch
HuaweiCPU UtilizationMonitors the CPU of Huawei S9312 SwitchesSNMPSwitch
HuaweiCPU UtilizationMonitors the CPU of Huawei USG9520 SwitchesSNMPSwitch
HuaweiCPU UtilizationMonitors the CPU of Huawei_AR3260 SwitchSNMPRouter
HuaweiCPU UtilizationMonitors the CPU of Huawei devicesSNMPRouter
HuaweiCPU UtilizationMonitor the CPU Utilization for Huawei devicesSNMPSwitch / Router
HuaweiCPU UtilizationMonitor the CPU Utilization for Huawei devicesSNMPSwitch / Router
HuaweiMemory UtilizationMonitors the Memory of Eudemon1000E FirewallSNMPFirewall
HuaweiMemory UtilizationMonitors the Memory of Huawei-Symantec-USG9310 RouterSNMPRouter
HuaweiMemory UtilizationMonitors the Memory of Huawei-AR1220 RoutersSNMPRouter
HuaweiMemory UtilizationMonitors the Memory of Huawei-AR2240 RoutersSNMPRouter
HuaweiMemory UtilizationMonitors the Memory of Huawei-epon-MA5600T SwitchSNMPSwitch
HuaweiMemory UtilizationMonitors the Memory of Huawei-epon-olt SwitchSNMPSwitch
HuaweiMemory UtilizationMemory Utilization for HuaweiSNMPFirewall
HuaweiMemory UtilizationMonitors the Memory of Huawei devicesSNMPSwitch
HuaweiMemory UtilizationMonitors the Memory of Huawei NE20E RouterSNMPRouter
HuaweiMemory UtilizationMonitors the Memory of Huawei-NE40-4 RouterSNMPRouter
HuaweiMemory UtilizationMemory Utilization for HuaweiSNMPRouter
HuaweiMemory UtilizationMonitors the Memory of Huawei-Quidway-Router-R2621 RouterSNMPRouter
HuaweiMemory UtilizationMemory Utilization for HuaweiSNMPSwitch
HuaweiMemory UtilizationMonitors the Memory of Huawei devicesSNMPSwitch
HuaweiMemory UtilizationMonitor the Memory Utilization for Huawei devicesSNMPSwitch
HuaweiMemory UtilizationMonitors the Memory of Huawei S3352 SwitchesSNMPSwitch
HuaweiMemory UtilizationMemory Utilization for HuaweiSNMPSwitch
HuaweiMemory UtilizationMemory Utilization for HuaweiSNMPSwitch
HuaweiMemory UtilizationMonitors the Memory of Huawei-S7703 switchSNMPSwitch
HuaweiMemory UtilizationMemory Utilization for HuaweiSNMPSwitch
HuaweiMemory UtilizationMonitors the Memory of Huawei-S8505 SwitchSNMPSwitch
HuaweiMemory UtilizationMonitor the Memory Utilization for Huawei devicesSNMPSwitch
HuaweiMemory UtilizationMonitors the Memory of Huawei S9303 SwitchesSNMPSwitch
HuaweiMemory UtilizationMonitors the Memory of Huawei S9312 SwitchesSNMPSwitch
HuaweiMemory UtilizationMonitors the Memory of Huawei-USG9300 RouterSNMPRouter
HuaweiMemory UtilizationMonitors the Memory of Huawei USG9520 SwitchesSNMPSwitch
HuaweiMemory UtilizationMonitors the Memory of Huawei_AR3260 SwitchSNMPRouter
HuaweiMemory UtilizationMonitors the Memory of Huawei devicesSNMPRouter
HuaweiMemory UtilizationMonitors the Memory of Huawei_SRG1220 RoutersSNMPRouter
HuaweiMemory UtilizationMonitor the Memory Utilization for Huawei devicesSNMPSwitch
HuaweiMemory UtilizationMonitor the Memory Utilization for Huawei devicesSNMPSwitch / Router
IBMIBM Interface Rx TrafficMonitors the total number of octets received on the interfaceSNMPServer
IBMIBM Interface Tx TrafficMonitors the total number of octets transmitted out of the interfaceSNMPServer
IBMIBM InterfaceRx UtilizationMonitors the utilization of the interface based on the incoming trafficSNMPServer
IBMIBM InterfaceTx UtilizationMonitors the utilization of the interface based on the outgoing trafficSNMPServer
IBMiBMPSGPhysicalMemoryDataWidthMonitoring the data width used in this Physical MemorySNMPServer
IBMiBMPSGPhysicalMemoryTotalWidthMonitoring the total width used in this Physical MemorySNMPServer
IBMIBMPSGProcessorCurrentClockSpeedCurrent clock speed of this ProcessorSNMPServer
IBMIBMPSGTachometerCurrentReadingMonitors the fan speedSNMPServer
IBMIBMPSGTemperatureSensorCurrentReadingMonitors the Current Reading of this Temperature SensorSNMPServer
IBMIBMPSGVoltageSensorCurrentReadingMonitors the Current Reading of this Voltage SensorSNMPServer
IBMTotal Memory Width UtilizationMonitoring the total used width utilization of this Physical MemorySNMPServer
JuniperActive Session CountDescriptionSNMPFirewall
JuniperAverage delayAverage round-trip time (in milliseconds) between two measurement points.SNMPSwitch / Router
JuniperBuffer UtilizationOperating Buffer UtilizationSNMPSwitch / Firewall
JuniperComponent operating statusOperational status of a router hardware componentSNMPSwitch / Router
JuniperComponent operating temperatureOperational temperature of a hardware component, in CelsiusSNMPNetworking Device
JuniperCPU loadAverage utilization over the past minute of a CPU.SNMPNetworking Device
JuniperCPU UtilizationMonitors the CPU of FirewallSNMPFirewall
JuniperCPU UtilizationMonitors the CPU of Juniper-EX SwitchSNMPSwitch
JuniperCPU UtilizationMonitors the CPU of Juniper-SRX650 FirewallSNMPFirewall
JuniperCPU Utilization(Last 1 min)Monitors the Last one minute CPU utilization in percentage.SNMPFirewall
JuniperCPU Utilization(Last 15 min)Monitors the Last fifteen minutes CPU utilization in percentage.SNMPFirewall
JuniperCPU Utilization(Last 5 min)Monitors the Last five minutes CPU utilization in percentage.SNMPFirewall
JuniperDRAM sizeDRAM sizeSNMPNetworking Device
JuniperFRU stateOperational status of each field-replaceable unit (FRU)SNMPSwitch / Router
JuniperJuniper ConnectionsMonitors the Connections of FirewallSNMPFirewall
JuniperJuniper TemperatureTemperature MeasurementSNMPSwich / Router
JuniperLabel Switched Path stateOperational state of an MPLS label-switched pathSNMPRouter
JuniperLSP utilizationUtilization of the MPLS label-switched pathSNMPSwitch / Router
JuniperMemory UtilizationMonitors the Memory of Juniper-EX SwitchSNMPSwitch
JuniperMemory UtilizationMonitors the Memory of Juniper SwitchesSNMPSwitch
JuniperMemory UtilizationMonitors the Memory of Juniper-SRX650 FirewallSNMPFirewall
JuniperMemory utilizationUtilization of memory on the Routing Engine and FPC.SNMPSwich / Router
JuniperMemory UtilizationMonitors the Memory UtilizationSNMPSwitch / Firewall
JuniperMemory UtilizationMonitors the Memory of FirewallSNMPFirewall
JuniperOutbound CountersNumber of bytes belonging to the specified forwarding class that were transmitted on the specified virtual circuitSNMPSwitch / Router
JuniperOutbound Counters for non-ATMNumber of transmitted bytes or packets per interface per forwarding classSNMPRouter
JuniperOutput queue sizeSize, in packets, of each output queue per forwarding class, per interfaceSNMPSwitch / Router
JuniperRate of tail dropped packetsRate of tail-dropped packets per output queue, per forwarding class, per interfaceSNMPRouter
JuniperRedundancy switchoverTotal number of redundancy switchovers reported by this entitySNMPSwich / Router
JuniperRss Session FailureCountMonitors the rss session failure count.SNMPFirewall
JuniperRSS SessionCountMonitor the allocate rss session numberSNMPFirewall
KYLANDCPU UtilizationCPU Utilization for KYLANDSNMPSwitch
KYLANDMemory UtilizationMemory Utilization for KYLANDSNMPSwitch
leadsecCPU UtilizationMonitors the CPU of leadsec FirewallSNMPFirewall
leadsecMemory UtilizationMonitors the Memory of leadsec FirewallSNMPFirewall
MAIPUCPU UtilizationCPU Utilization for MAIPUSNMPSwich / Router
MAIPUCPU UtilizationMonitors the CPU of MAIPU S4126E SwitchSNMPSwitch
MAIPUCPU UtilizationMonitors the CPU of MAIPU S4128E SwitchSNMPSwitch
MAIPUMemory UtilizationMemory Utilization for MAIPUSNMPSwich / Router
MAIPUMemory UtilizationMonitors the Memory of MAIPU S4126E SwitchSNMPSwitch
MAIPUMemory UtilizationMonitors the Memory of MAIPU S4128E SwitchSNMPSwitch
MAIPUTemperatureMonitors the Temperature of MAIPU RouterSNMPRouter
MGEBattery InstalledBattery InstalledSNMPUPS
MGEBattery sys ShutdownBattery sys Shutdown DurationSNMPUPS
MGEUPS LoadMonitors UPS LoadSNMPUPS
MicrosoftBytes ReceivedNumber of bytes the server has received from the network. This property indicates how busy the server isWMIServer
MicrosoftBytes TotalNumber of bytes the server has sent to and received from the network, an overall indication of how busy the server isWMIServer
MicrosoftBytes TransmittedNumber of bytes the server has received from the network. This property indicates how busy the server isWMIServer
MicrosoftCache Hit RatioMonitors the cache hit ratioSNMPServer
MicrosoftContextSwitchesRate of switches from one thread to another. Thread switches can occur either inside of a single process or across processesWMIServer
MicrosoftCPU Idle TimeMonitors the CPU Idle ( MilliSecond ) of HyperV Host using WMIVIWMIServer
MicrosoftCPU ReadyMonitors the CPU Ready ( MilliSecond ) of HyperV Guest using WMIVIWMIServer
MicrosoftCPU Usage MHz per coreMonitors the CPU Usage MHz per core of HyperV Guest using WMIVIWMIServer
MicrosoftCPU UsedMonitors the CPU Used ( MilliSecond ) of HyperV Guest using WMIVIWMIServer
MicrosoftCPU Used TimeMonitors the CPU Used ( MilliSecond ) of HyperV Host using WMIVIWMIServer
MicrosoftCPU UtilizationMonitors the Overall CPU Utilization of HyperV Host using WMIVIWMIServer
MicrosoftCPU UtilizationMonitors the CPU Utilization of HyperV Guest using WMIVIWMIServer
MicrosoftCPU UtilizationMonitors the CPU Utilization using WMIWMIServer / Desktop
MicrosoftCPU Utilization Per CoreMonitors the CPU Utilization per Core of HyperV Host using WMIVIWMIServer
MicrosoftCPU WaitMonitors the CPU Wait ( MilliSecond ) of HyperV Guest using WMIVIWMIServer
MicrosoftData Space of DBMonitors the total data size in DatabaseSNMPServer
MicrosoftData Transaction LogSpaceMonitors the data transaction logspaceSNMPServer
MicrosoftDelivered Outbound MessagesMonitors the delivered outbound messagesSNMPServer
MicrosoftDisk I/O UsageMonitors Disk I/O Usage of HyperV Host using WMIVIWMIServer
MicrosoftDisk Queue LengthNumber of requests outstanding on the diskWMIServer
MicrosoftDisk Read LatencyMonitors Disk Read Latency of HyperV Host using WMIVIWMIServer
MicrosoftDisk Read RequestsMonitors Disk Read Requests of HyperV Host using WMIVIWMIServer
MicrosoftDisk Read RequestsMonitors Disk Read Requests of HyperV Guest using WMIVIWMIServer
MicrosoftDisk Read SpeedMonitors Disk Read Speed of HyperV Host using WMIVIWMIServer
MicrosoftDisk Read SpeedMonitors Disk Read Speed of HyperV Guest using WMIVIWMIServer
MicrosoftDisk ReadsRate of read operations on the disk per SecondWMIServer / Desktop
MicrosoftDisk Space UsageMonitors Disk Space Usage Latency of HyperV Host using WMIVIWMIServer
MicrosoftDisk UtilizationMonitors the Disk Utilization using WMIWMIServer / Desktop
MicrosoftDisk Write LatencyMonitors Disk Write Latency of HyperV Host using WMIVIWMIServer
MicrosoftDisk Write RequestsMonitors Disk Write Requests of HyperV Host using WMIVIWMIServer
MicrosoftDisk Write RequestsMonitors Disk Write Requests of HyperV Guest using WMIVIWMIServer
MicrosoftDisk Write SpeedMonitors Disk Write Speed of HyperV Host using WMIVIWMIServer
MicrosoftDisk Write SpeedMonitors Disk Write Speed of HyperV Guest using WMIVIWMIServer
MicrosoftDisk WritesRate of write operations on the diskWMIServer / Desktop
MicrosoftFile Read BytesOverall rate at which bytes are read to satisfy file system read requests to all devices on the computer, including read requests from the file system cacheWMIServer / Desktop
MicrosoftFile Read OperationsCombined rate of file system read requests to all devices on the computer, including requests to read from the file system cacheWMIServer / Desktop
MicrosoftFile Write BytesOverall rate at which bytes are written to satisfy file system write requests to all devices on the computer, including write requests to the file system cacheWMIServer / Desktop
MicrosoftFile Write OperationsCombined rate of the file system write requests to all devices on the computer, including requests to write to data in the file system cacheWMIServer / Desktop
MicrosoftFree Disk Space in GBMonitors the Free disk space in GB using WMIWMIServer / Desktop
MicrosoftFree Disk Space in MBMonitors the Free disk space in MB using WMIWMIServer / Desktop
MicrosoftFree Physical MemoryPhysical memory currently unused and available, in Mega BytesWMIServer / Desktop
MicrosoftIdle TimePercentage of time during the sample interval that the processor was idle. Not applicable for Windows XP and Windows 2000 devices.WMIServer / Desktop
MicrosoftInbound Connection RateMonitors the inbound connection rateSNMPServer
MicrosoftIO Batch WritesMonitors the IO batch writesSNMPServer
MicrosoftIO Outstanding ReadsMonitors the IO outstanding readsSNMPServer
MicrosoftIO Outstanding WritesMonitors the IO outstanding writesSNMPServer
MicrosoftIO Page ReadsMonitors the IO page readsSNMPServer
MicrosoftMemory ActiveMonitors Memory Active in KB of HyperV Host using WMIVIWMIServer
MicrosoftMemory ConsumedMonitors Memory Consumed in KB of HyperV Guest using WMIVIWMIServer
MicrosoftMemory OverheadMonitors Memory OverHead in KB of HyperV Guest using WMIVIWMIServer
MicrosoftMemory UsedMonitors Memory Used in KB of HyperV Host using WMIVIWMIServer
MicrosoftMemory UtilizationMonitors Memory Usage of HyperV Host using WMIVIWMIServer
MicrosoftMemory UtilizationMonitors Memory Usage of HyperV Guest using WMIVIWMIServer
MicrosoftMemory UtilizationMonitors the Memory Utilization using WMIWMIServer / Desktop
MicrosoftNetwork Packets ReceivedMonitors Network Packets Received of HyperV Host using WMIVIWMIServer
MicrosoftNetwork Packets ReceivedMonitors Network Packets Received of HyperV Guest using WMIVIWMIServer
MicrosoftNetwork Packets TransmittedMonitors Network Packets Transmitted of HyperV Host using WMIVIWMIServer
MicrosoftNetwork Packets TransmittedMonitors Network Packets Transmitted of HyperV Guest using WMIVIWMIServer
MicrosoftNetwork Received SpeedMonitors Network Received Speed of HyperV Host using WMIVIWMIServer
MicrosoftNetwork Received SpeedMonitors Network Received Speed of HyperV Guest using WMIVIWMIServer
MicrosoftNetwork Transmitted SpeedMonitors Network Transmitted Speed of HyperV Host using WMIVIWMIServer
MicrosoftNetwork Transmitted SpeedMonitors Network Transmitted Speed of HyperV Guest using WMIVIWMIServer
MicrosoftNetwork UsageMonitors Network Usage of HyperV Host using WMIVIWMIServer
MicrosoftNetwork UsageMonitors Network Usage of HyperV Guest using WMIVIWMIServer
MicrosoftNon-delivery Reports (Total Inbound)Monitors the total inbound non-delivery reportSNMPServer
MicrosoftNon-delivery Reports (Total Outbound)Monitors the total outbound non-delivery reportSNMPServer
MicrosoftOutbound Connection RateMonitors the outbound connection rateSNMPServer
MicrosoftPage FaultsOverall rate at which faulted pages are handled by the processorWMIServer / Desktop
MicrosoftPage ReadsNumber of times the disk was read to resolve hard page faultsWMIServer / Desktop
MicrosoftPage WritesOverall rate at which faulted pages are handled by the processorWMIServer / Desktop
MicrosoftPages Per SecondNumber of pages read from or written to the disk to resolve hard page faultsWMIServer / Desktop
MicrosoftPartition Details of the Device(%)Monitoring the usage in each partition of the Device using WMI.WMIServer / Desktop
MicrosoftPrivileged TimePercentage of non-idle processor time spent in privileged modeWMIServer / Desktop
MicrosoftProcessor Queue LengthNumber of threads in the processor queueWMIServer / Desktop
MicrosoftProcessor TimePercentage of time that the processor is executing a non-idle threadWMIServer / Desktop
MicrosoftTotal Active LocksMonitors the total active locksSNMPServer
MicrosoftTotal Blocking LocksMonitors the total blocking locksSNMPServer
MicrosoftTotal IO TransactionsMonitors the total IO transactionsSNMPServer
MicrosoftTotal Messages Received (from internet)Monitors the total messages received from internetSNMPServer
MicrosoftTotal Msgs (awaiting final delivery)Monitors the total awaiting messages for deliverySNMPServer
MicrosoftTotal Msgs Queued for delivery (to internet)Monitors the to total messages queued for delivery to internetSNMPServer
MicrosoftTotal Open User ConnectionsMonitors the total open user connectionsSNMPServer
MicrosoftTotal Size of DBMonitors the total database sizeSNMPServer
MicrosoftTotal Size of the Msgs (awaiting final delivery)Monitors the total size of the awaiting messages for deliverySNMPServer
MicrosoftUnused Space of DBMonitors the unused space in databaseSNMPServer
MicrosoftUsed Disk Space in GBMonitors the used disk space in GB using WMIWMIServer / Desktop
MicrosoftUsed Disk Space in MBMonitors the used disk space in MB using WMIWMIServer / Desktop
MicrosoftUsed LogSpaceMonitors the used logspaceSNMPServer
MicrosoftUser TimePercentage of non-idle processor time spent in user modeWMIServer / Desktop
NetApp, Inc.Active Disk CountMonitors the number of disks which are currently active, including parity disks.SNMPStorage
NetApp, Inc.Active snapvault destinations.Monitors the number of active snapvault destinationsSNMPStorage
NetApp, Inc.Active snapvault sourcesMonitors the number of active snapvault sources.SNMPStorage
NetApp, Inc.Aggregate AvailableMonitors the aggregate available in bytesSNMPStorage
NetApp, Inc.Aggregate StateMonitors the current state of the aggregatesSNMPStorage
NetApp, Inc.Aggregate UsedMonitors the aggregate used in bytesSNMPStorage
NetApp, Inc.Aggregate Used PercentageMonitors the aggregate used percentageSNMPStorage
NetApp, Inc.Battery StatusMonitors the indication of the current status of the NVRAM batteries. { ok ( 1 ) , partiallyDischarged ( 2 ) , fullyDischarged ( 3 ) , notPresent ( 4 ) , nearEndOfLife ( 5 ) , atEndOfLife ( 6 ) , unknown ( 7 ) , overCharged ( 8 ) , fullyCharged ( 9 ) }SNMPStorage
NetApp, Inc.Cache AgeAge in minutes of the oldest read-only blocks in the buffer cache.SNMPStorage
NetApp, Inc.CPU UtilizationMonitors the percent of time that the CPU has been doing useful work since the last time a client requested the cpuBusyTimePerCent.SNMPStorage
NetApp, Inc.Disk Read BytesMonitors the total number of bytes read from disk since the last boot.SNMPStorage
NetApp, Inc.Disk StateMonitors the current state of the disksSNMPStorage
NetApp, Inc.Disk Write BytesMonitors the total number of bytes written to disk since the last boot.SNMPStorage
NetApp, Inc.Failed Disk countMonitors the number of disks which are currently broken.SNMPStorage
NetApp, Inc.Fan StatusMonitors the Count of the number of chassis fans which are not operating within the recommended RPM range.SNMPStorage
NetApp, Inc.FCP OperationsMonitors the total number of FCP ops handled since the last bootSNMPStorage
NetApp, Inc.FCP Read BytesMonitors the total number of bytes read via fcp since the last boot.SNMPStorage
NetApp, Inc.FCP Write BytesMonitors the total number of bytes written via fcp since the last boot.SNMPStorage
NetApp, Inc.Global StatusMonitors the overall status of the appliance.{ other ( 1 ) , unknown ( 2 ) , ok ( 3 ) , nonCritical ( 4 ) , critical ( 5 ) , nonRecoverable ( 6 ) }SNMPStorage
NetApp, Inc.ISCSI OperationsMonitors the total number of iSCSI ops handled since the last bootSNMPStorage
NetApp, Inc.ISCSI Read BytesMonitors the total number of bytes read via iscsi since the last boot.SNMPStorage
NetApp, Inc.ISCSI Write BytesMonitors the total number of bytes written via iscsi since the last boot.SNMPStorage
NetApp, Inc.LUN StateMonitors the current state of the lun'sSNMPStorage
NetApp, Inc.NetApp TemperatureMonitors the indication of whether the hardware is currently operating outside of its recommended temperature range. { no ( 1 ) , yes ( 2 ) }.SNMPStorage
NetApp, Inc.Power Supply StatusMonitors Count of the number of power supplies which are in degraded mode. { no ( 1 ) , yes ( 2 ) }SNMPStorage
NetApp, Inc.qrV Files UsedMonitors the current number of files used for this qrVEntry.SNMPStorage
NetApp, Inc.qrVEntry Used bytesMonitors the current number of KBytes used for this qrVEntry.SNMPStorage
NetApp, Inc.Quota State StatusMonitors whether quotas are ON, OFF or initializing. quotaStateOff {( 1 ) , quotaStateOn ( 2 ) , quotaStateInit ( 3 ) }SNMPStorage
NetApp, Inc.Snapvault StatusMonitors the current transfer status of the snapvault relationship.SNMPStorage
NetApp, Inc.Snapvault Total Primary FailuresMonitors the total number of failed snapvault transfers on the snapvault primary. Persistent across reboot.SNMPStorage
NetApp, Inc.Snapvault Total Primary SuccessesMonitors the total number of successful snapvault transfers from the snapvault primary. Persistent across reboot.SNMPStorage
NetApp, Inc.Snapvault Total Secondary FailuresMonitors total number of failed snapvault transfers on the snapvault secondary. Persistent across reboot.SNMPStorage
NetApp, Inc.Snapvault Total Secondary SuccessesMonitors the total number of successful snapvault transfers from the snapvault secondary. Persistent across reboot.SNMPStorage
NetApp, Inc.Total DiskCountMonitors the total number of disks on the system.SNMPStorage
NetApp, Inc.Volume AvailableMonitors the volume available in bytesSNMPStorage
NetApp, Inc.volume available bytesmonitors the total disk space in kbytes that is free for use on the referenced file system.SNMPStorage
NetApp, Inc.Volume StateMonitors the current state of the volumesSNMPStorage
NetApp, Inc.Volume UsedMonitors the volume used in bytesSNMPStorage
NetApp, Inc.Volume Used PercentageMonitors the volume used percentageSNMPStorage
NetScreen Technologies, Inc.Active Session CountActive Session Count DescSNMPFirewall
NetScreen Technologies, Inc.CPU UtilizationMonitors the CPU utilizationSNMPFirewall
NetScreen Technologies, Inc.Memory UtilizationMonitors the Memory UtilizationSNMPFirewall
NovellCache maximum sizeCache maximum size in Kbytes, this is hard limit parameterSNMPServer
NovellContact failuresThe number of failures since the last time an attempt to contact the peer eDirectory Server was successfulSNMPServer
NovellCumulative failuresCumulative failures in contacting the peer eDirectory Server since the creation of this entrySNMPServer
NovellCumulative successesCumulative successes in contacting the peer eDirectory Server since the creation of this entrySNMPServer
NovellDatabase SizeCurrent size of the eDirectory DatabaseSNMPServer
NovellDynamic Cache MemoryDynamic Cache Adjust percentageSNMPServer
NovellEntries in cacheNumber of Entries in cacheSNMPServer
NovellEntry hitsNumber of Entry hitsSNMPServer
NovellEntry missesNumber of Entries examined to determine missesSNMPServer
NovellFetched replication updatesNumber of replication updates fetched or received from eDirectory ServersSNMPServer
NovellIncoming trafficIncoming traffic on the interfaceSNMPServer
NovellOperations forwardedNumber of operations forwarded by this eDirectory Server to other eDirectory ServersSNMPServer
NovellOutgoing trafficOutgoing traffic on the interfaceSNMPServer
NovellReceived add Entry requestsNumber of addEntry requests receivedSNMPServer
NovellReceived read requestsNumber of read requests receivedSNMPServer
NovellRejected bind requestsNumber of bind requests that have been rejected due to inappropriate authentication or invalid credentialsSNMPServer
NovellSent replication updatesNumber of replication updates sent to or taken by eDirectory ServersSNMPServer
NovellUnauthenticated requests receivedNumber of unauthenticated/anonymous bind requests receivedSNMPServer
NsfocusCPU UtilizationMonitors the CPU of Nsfocus FirewallSNMPFirewall
NsfocusMemory UtilizationMonitors the Memory of Nsfocus FirewallSNMPFirewall
OpZoonCPU UtilizationMonitors the CPU of OpZoon SwitchSNMPSwitch
OpZoonCPU UtilizationMonitors the CPU of OpZoon PE-3810 RouterSNMPSwitch
OpZoonCPU UtilizationMonitors the CPU of OpZoon SwitchSNMPSwitch
OpZoonMemory UtilizationMonitors the Memory of OpZoon SwitchSNMPSwitch
OpZoonMemory UtilizationMonitors the Memory of OpZoon PE-3810 RouterSNMPSwitch
OpZoonMemory UtilizationMonitors the Memory of OpZoon SwitchSNMPSwitch
OracleDataFile DiskReadsMonitors the number of disk reads in data fileSNMPServer
OracleDataFile DiskWritesMonitors the number of disk writes in data fileSNMPServer
OracleDataFileSize AllocatedMonitors the allocated data file sizeSNMPServer
OracleLibrary CacheGetsMonitors the number of request for Library CacheGetsSNMPServer
OracleLibrary CacheInvalidationsMonitors the number of CacheInvalidationsSNMPServer
OracleLibrary CacheReloadsMonitors the number of reloadsSNMPServer
OracleNumber of UserCommitsMonitors the number of commitsSNMPServer
OracleOraDbSysUserRollbacksMonitors the number of rollbacksSNMPServer
OracleTableScan BlocksMonitors the number of blocksSNMPServer
OracleTablespace AllocatedMonitors the total table space allocatedSNMPServer
OracleTablespace Largest AvailableMonitors the largest available tablespaceSNMPServer
OracleTablespace UsedMonitors the total tablespace usedSNMPServer
RadwareCPU UtilizationCPU Utilization for RadwareSNMPSwitch
RadwareMemory UtilizationMonitors the Memory of Radware AD-508 SwitchesSNMPSwitch
RadwareMemory UtilizationMonitors the Memory of Radware DP-502 SwitchesSNMPSwitch
Research In MotionAverage Response TimeMonitors the average response time (in milliseconds) for operations for users on this mail server in the last 10 minutes. Applies to BlackBerry Enterprise Server for Lotus Domino only.SNMPServer
Research In MotionFailed ConnectionsMonitors the number of failed connection attempts to this mail server in the last 10 minutes. Applies to BlackBerry Enterprise Server for Lotus Domino only.SNMPServer
Research In MotionMDS Connection FailureMonitors the number of failed connections initiated by MDS to another address/service.SNMPServer
Research In MotionMDS Connection SuccessMonitors the number of successful connections initiated by MDS to another address/service.SNMPServer
Research In MotionMDS Push ConnectionsMonitors the number of push server connections.SNMPServer
Research In MotionMessages received per minMonitors the total number of messages delivered to handhelds per min.SNMPServer
Research In MotionMessages sent per minMonitors the total number of messages sent from handhelds per min.SNMPServer
Research In MotionTotal License ConfiguredMonitors the total number of licenses installed on the server.SNMPServer
Research In MotionTotal License UsedMonitors the total number of licenses in use currently.SNMPServer
Research In MotionTotal messages pendingMonitors the total number of messages delivered to handhelds per min.SNMPServer
Research In MotionTotal messages receivedMonitors the total number of messages delivered to handhelds.SNMPServer
Research In MotionTotal messages sentMonitors the total number of messages sent from handhelds.SNMPServer
Research In MotionTotal UsersMonitors the number of users who are homed on this mail server. Applies to BlackBerry Enterprise Server for Lotus Domino only.SNMPServer
Riverbed Technology, Inc.Active Connection(s)Monitors the current number of active (optimized) connections.SNMPWAN Accelerator
Riverbed Technology, Inc.BW aggregate in LANMonitors the total optimized bytes across all application ports, in the WAN to LAN direction since the last restart of service, as measured on the LAN side.SNMPWAN Accelerator
Riverbed Technology, Inc.BW aggregate in WANMonitors the total optimized bytes across all application ports, in the WAN to LAN direction since the last restart of service, as measured on the WAN side.SNMPWAN Accelerator
Riverbed Technology, Inc.BW aggregate out LANMonitors the total optimized bytes across all application ports, in the LAN to WAN direction since the last restart of service, as measured on the LAN side.SNMPWAN Accelerator
Riverbed Technology, Inc.BW aggregate out WANMonitors the total optimized bytes across all application ports, in the LAN to WAN direction since the last restart of service, as measured on the WAN side.SNMPWAN Accelerator
Riverbed Technology, Inc.BW Passthrough InMonitors the Passthrough bytes in WAN to LAN direction.SNMPWAN Accelerator
Riverbed Technology, Inc.BW Passthrough OutMonitors the Passthrough bytes in LAN to WAN direction.SNMPWAN Accelerator
Riverbed Technology, Inc.BW Passthrough totalMonitors the total passthrough bytes.SNMPWAN Accelerator
Riverbed Technology, Inc.CPU Usage(5 mins avg)Monitors the Five-minute CPU load in hundreths.SNMPWAN Accelerator
Riverbed Technology, Inc.CPU UtilizationMonitors the percentage CPU utilization, aggregated across all CPUs, rolling average over the past minute.SNMPWAN Accelerator
Riverbed Technology, Inc.dsCostPerSegmentMonitors the Cost per segment expressed in microseconds.SNMPWAN Accelerator
Riverbed Technology, Inc.dsHits TotalMonitors the total number of datastore hits since last restart of service.SNMPWAN Accelerator
Riverbed Technology, Inc.dsMiss TotalMonitors the total number of datastore misses since last restart of service.SNMPWAN Accelerator
Riverbed Technology, Inc.Established Connection(s)Monitors the current number of established (optimized) connections.SNMPWAN Accelerator
Riverbed Technology, Inc.Half Closed Connection(s)Monitors the Current total number of half-closed (optimized) connections.SNMPWAN Accelerator
Riverbed Technology, Inc.Half Opened Connection(s)Monitors the current total number of half-opened (optimized) connections.SNMPWAN Accelerator
Riverbed Technology, Inc.Optimization Service StatusMonitors the Current status of the optimization service.SNMPWAN Accelerator
Riverbed Technology, Inc.Optimized Connection(s)Monitors the current total number of optimized connections.SNMPWAN Accelerator
Riverbed Technology, Inc.Pass-Through Connection(s)Monitors the current total number of pass-through connections.SNMPWAN Accelerator
Riverbed Technology, Inc.Steelhead TemperatureMonitors the temperature of the system(C).SNMPWAN Accelerator
Riverbed Technology, Inc.System Health StatusMonitors the current health of the system. The value is one amongst Healthy, Admission Control, Degraded, Critical.SNMPWAN Accelerator
Riverbed Technology, Inc.Total Connection(s)Monitors the total number of connections.SNMPWAN Accelerator
RuiJieCPU UtilizationCPU Utilization for RuiJieSNMPSwitch
RuiJieMemory UtilizationMemory Utilization for RuiJieSNMPSwitch
SecGateCPU UtilizationMonitors the CPU of SecGate FirewallSNMPFirewall
SecGateMemory UtilizationMonitors the Memory of SecGate FirewallSNMPFirewall
SOCOMEC UPSBattery CapacityEstimate of the battery charge remaining expressed as a percent of full charge.SNMPUPS
SOCOMEC UPSBattery CapacityEstimate of the battery charge remaining expressed in percentSNMPUPS
SOCOMEC UPSBattery CapacityEstimate of the battery charge remaining expressed in percentSNMPUPS
SOCOMEC UPSBattery CapacityEstimate of the battery charge remaining expressed in percentSNMPUPS
SOCOMEC UPSBattery Negative VoltageBattery negative voltage in voltsSNMPUPS
SOCOMEC UPSBattery Positive VoltageBattery positive voltage in voltsSNMPUPS
SOCOMEC UPSBattery VoltageBattery Voltage in volts.SNMPUPS
SOCOMEC UPSBattery VoltageBattery Voltage in voltsSNMPUPS
SOCOMEC UPSBattery VoltageBattery Voltage in voltsSNMPUPS
SOCOMEC UPSOutput Load Phase 1Monitor UPS Output Load Phase 1 expressed in percentSNMPUPS
SOCOMEC UPSOutput Load Phase 2Monitor UPS Output Load Phase 2 expressed in percentSNMPUPS
SOCOMEC UPSOutput Load Phase 3Monitor UPS Output Load Phase 3 expressed in percentSNMPUPS
SOCOMEC UPSOutput Load Rate Phase 1Monitor UPS Output Load Phase 1 expressed in percentSNMPUPS
SOCOMEC UPSOutput Load Rate Phase 1Monitor UPS Output Load Phase 1 expressed in percentSNMPUPS
SOCOMEC UPSOutput Load Rate Phase 2Monitor UPS Output Load Phase 2 expressed in percentSNMPUPS
SOCOMEC UPSOutput Load Rate Phase 3Monitor UPS Output Load Phase 3 expressed in percentSNMPUPS
SOCOMEC UPSUPS Output Load RateUPS Output Load Rate in %.SNMPUPS
SymbolUPS Battery currentCustom MonitorSNMPUPS
TainetCPU UtilizationMonitors the CPU of Tainet_Venus_2816 SwitchSNMPSwitch
TainetMemory UtilizationMonitors the Memory of Tainet_Venus_2816 SwitchSNMPSwitch
TopsecCPU UtilizationMonitors the CPU of TopSec FirewallSNMPFirewall
TopsecMemory UtilizationMonitors the Memory of TopSec FirewallSNMPFirewall
TopsecVPN-ConnectionsMonitors the VPN-Connections of TopSec FirewallSNMPFirewall
TrangoSU CountSU CountSNMPWireless
TrippLiteUPS ChargeMonitors UPS ChargeSNMPUPS
TrippLiteUPS LoadMonitors UPS LoadSNMPUPS
VENUSConnectionsMonitors the Connections of VENUS-VSOS-V2.6 FirewallSNMPFirewall
VENUSConnectionsMonitors the Connections of VENUS_FW FirewallSNMPFirewall
VENUSCPU UtilizationMonitors the CPU of VENUS-VSOS-V2.6 FirewallSNMPFirewall
VENUSCPU UtilizationMonitors the CPU of VENUS_FW FirewallSNMPFirewall
VENUSMemory UtilizationMonitors the Memory of VENUS-VSOS-V2.6 FirewallSNMPFirewall
VENUSMemory UtilizationMonitors the Memory of VENUS_FW FirewallSNMPFirewall
VmwareActive MemoryAmount of guest physical memory actively used.VIWebServiceServer
VmwareBalloon MemoryAmount of guest physical memory that is currently reclaimed from the VM through ballooning.VIWebServiceServer
VmwareCompressed MemoryAmount of memory compressed by ESX for VMVIWebServiceServer
VmwareConsumed MemoryAmount of memory consumed by a virtual machine,VIWebServiceServer
VmwareCPU Idle TimeTotal time that the CPU spent in an idle stateVIWebServiceServer
VmwareCPU ReadyTime that the virtual machine was ready, but could not get scheduled to run on the physical CPUVIWebServiceServer
VmwareCPU UsageSum of the actively used CPU of all powered on virtual machines on a host.VIWebServiceServer
VmwareCPU UsedTotal CPU usage By HostSystemVIWebServiceServer
VmwareCPU UsedTime accounted to the virtual machineVIWebServiceServer
VmwareCPU UtilizationActively used CPU of the host, as a percentage of the total available CPUVIWebServiceServer
VmwareCPU UtilizationActively used VCPU, as percentage of total available CPU. This is the host view of the CPU usageVIWebServiceServer
VmwareCPU WaitCPU time spent in wait stateVIWebServiceServer
VmwareDatastore Free SpaceVMware Datastore Freespace MonitorVIWebServiceServer
VmwareDatastore Read IOPsAverage number of read commands issued per second to the datastore during the collection interval.VIWebServiceServer
VmwareDatastore Read LatencyAverage amount of time for a read operation from the datastoreVIWebServiceServer
VmwareDatastore Read LatencyAverage amount of time for a read operation from the datastoreVIWebServiceServer
VmwareDatastore Read RateRate of reading data from the datastoreVIWebServiceServer
VmwareDatastore Read RequestsAverage number of read commands issued per second to the datastore during the collection interval.VIWebServiceServer
VmwareDatastore Read Requests RateAverage number of read commands issued per second to the datastoreVIWebServiceServer
VmwareDatastore Read SpeedRate of reading data from the datastore.VIWebServiceServer
VmwareDatastore Throughput UsageThe current bandwidth usage for the datastore or LUN.VIWebServiceServer
VmwareDatastore Write IOPsAverage number of write commands issued per second to the datastore during the collection intervalVIWebServiceServer
VmwareDatastore Write LatencyAverage amount of time for a write operation to the datastoreVIWebServiceServer
VmwareDatastore Write LatencyAverage amount of time for a write operation to the datastoreVIWebServiceServer
VmwareDatastore Write RateRate of reading data to the datastoreVIWebServiceServer
VmwareDatastore Write RequestsAverage number of write commands issued per second to the datastore during the collection interval.VIWebServiceServer
VmwareDatastore Write Requests RateAverage number of write commands issued per second to the datastoreVIWebServiceServer
VmwareDatastore Write SpeedRate of reading data to the datastore.VIWebServiceServer
VmwareDisk Bus ResetsNumber of SCSI-bus reset commands issued during the collection interval.VIWebServiceServer
VmwareDisk I/O UsageAggregated diskI/O rate for HostSystem over VMsVIWebServiceServer
VmwareDisk I/O UsageAggregated disk I/O rateVIWebServiceServer
VmwareDisk Max Total LatencyHighest latency value across all disks used by the host.VIWebServiceServer
VmwareDisk Read RateRate at which data is read from each disk on the vmVIWebServiceServer
VmwareDisk Read RequestsNumber of times data was read from each disk on the vmVIWebServiceServer
VmwareDisk Read SpeedRate at which data is Read from each LUN on the hostVIWebServiceServer
VmwareDisk ReadsNumber of times data was read from each LUN on the host.VIWebServiceServer
VmwareDisk Write RateRate at which data is written to each disk on the vmVIWebServiceServer
VmwareDisk Write RequestsNumber of times data written to each disk on the vmVIWebServiceServer
VmwareDisk Write SpeedRate at which data is written to each LUN on the hostVIWebServiceServer
VmwareDisk WritesNumber of times data written to each LUN on the hostVIWebServiceServer
VmwareDropped Received PacketsNumber of received packets dropped during the collection interval.VIWebServiceServer
VmwareDropped Transmitted PacketsNumber of transmitted packets dropped during the collection interval.VIWebServiceServer
VmwareMemory ActiveSum of all active metrics for all powered-on virtual machines plus vSphere servicesVIWebServiceServer
VmwareMemory Compression RateRate of memory compression for the VMVIWebServiceServer
VmwareMemory ConsumedAmount of machine memory used on the hostVIWebServiceServer
VmwareMemory Decompression RateRate of memory decompression for the virtual machineVIWebServiceServer
VmwareMemory GrantedAmount of Granted to Entities by HostSystemVIWebServiceServer
VmwareMemory OverheadTotal of all overhead metrics for powered-on virtual machines, the overhead of running vSphere services on the host.VIWebServiceServer
VmwareMemory SwapIn RateRate at which memory is swapped from disk into active memoryVIWebServiceServer
VmwareMemory SwapOut RateRate at which memory is being swapped from active memory to diskVIWebServiceServer
VmwareMemory UsagePercentage of available machine memory UsedVIWebServiceServer
VmwareMemory UsageAmount of machine memory used by the VMkernel to run the VMVIWebServiceServer
VmwareNetwork Packets ReceivedThe number of packets received by each vNIC on the VMVIWebServiceServer
VmwareNetwork Packets TransmittedNumber of packets transmitted by each vNIC on the virtual machineVIWebServiceServer
VmwareNetwork Received PacketsNumber of packets Received during the collection interval.VIWebServiceServer
VmwareNetwork Received RateThe rate at which data is received across each physical NIC instance on the host.VIWebServiceServer
VmwareNetwork Received RateThe rate at which data is received across the VMs vNICVIWebServiceServer
VmwareNetwork Transmitted PacketsNumber of packets Transmitted during the collection interval.VIWebServiceServer
VmwareNetwork Transmitted RateThe rate at which data is transmitted across each physical NIC instance on the host.VIWebServiceServer
VmwareNetwork Transmitted RateThe rate at which data is transmitted across the VMs vNICVIWebServiceServer
VmwareNetwork UsageSum of data transmitted and received across all physical NIC instances connected to the host.VIWebServiceServer
VmwareNetwork UsageSum of data transmitted and received across all vNIC instances connected to the VMVIWebServiceServer
VmwareOverhead MemoryAmount of machine memory used by the VMkernel to run the VMVIWebServiceServer
VmwareShared MemorySum of all shared metrics for all powered-on virtual machines, plus amount for vSphere services on the host.VIWebServiceServer
VmwareShared MemoryAmount of guest physical memory shared with other VMsVIWebServiceServer
VmwareSwapped MemoryCurrent amount of guest physical memory swappedout to the VMs swap file by the VMkernel.VIWebServiceServer
VmwareSwapped Used MemoryAmount of memory that is used by swap. Sum of memory swapped of all powered on VMs and vSphere services on the host.VIWebServiceServer
VmwareTotal Disk LatencyAverage amount of time taken to process a SCSI command issued from/by the Guest OS to the VMVIWebServiceServer
VmwareTotal Disk Read LatencyAverage amount of time takento process a SCSI read command issued from GuestOS to the VMVIWebServiceServer
VmwareTotal Disk Write LatencyAverage amount of time taken to process a SCSI read command issued by GuestOS to the VMVIWebServiceServer
YAMAHANVR500_CPU Utilization (1 Min)Custom MonitorSNMPSwitch
YAMAHANVR500_CPU Utilization (5 Min)Custom MonitorSNMPSwitch
YAMAHANVR500_CPU Utilization (5 Sec)Custom MonitorSNMPSwitch
YAMAHANVR500_Memory UtilizationCustom MonitorSNMPSwitch
YAMAHARTX1200_CPU Utlization (1 Min)Custom MonitorSNMPRouter
YAMAHARTX1200_CPU Utlization (5 Min)Custom MonitorSNMPRouter
YAMAHARTX1200_CPU Utlization (5 Sec)Custom MonitorSNMPRouter
YAMAHARTX1200_Inbox TemperatureCustom MonitorSNMPRouter
YAMAHARTX1200_Memory UtlizationCustom MonitorSNMPRouter
YAMAHARTX810_CPU Utilization (1 Min)Custom MonitorSNMPRouter
YAMAHARTX810_CPU Utilization (5 Min)Custom MonitorSNMPRouter
YAMAHARTX810_CPU Utilization (5 Sec)Custom MonitorSNMPRouter
YAMAHARTX810_Memory UtlizationCustom MonitorSNMPRouter
ZhongXingCPU UtilizationCPU Utilization for ZhongXingSNMPSwitch
ZhongXingCPU UtilizationCPU Utilization for ZhongXingSNMPSwitch
ZhongXingCPU UtilizationCPU Utilization for ZhongXingSNMPSwitch
ZhongXingCPU UtilizationCPU Utilization for ZhongXingSNMPSwitch
ZhongXingMemory UtilizationMemory Utilization for ZhongXingSNMPSwitch
ZhongXingMemory UtilizationMemory Utilization for ZhongXingSNMPSwitch
ZhongXingMemory UtilizationMemory Utilization for ZhongXingSNMPSwitch
ZhongXingMemory UtilizationMemory Utilization for ZhongXingSNMPSwitch
ZTECPU UtilizationMonitors the CPU of ZTE-2850-26TM SwitchSNMPSwitch
ZTECPU UtilizationCPU Utilization for ZTESNMPSwitch
ZTECPU UtilizationMonitors the CPU of ZTE-ZXPON-EPON-ONU SwitchSNMPSwitch
ZTECPU UtilizationMonitors the CPU of ZTE-ZXR10-2826E SwitchSNMPSwitch
ZTECPU UtilizationMonitors the CPU of ZTE-ZXR10-2826S-LE SwitchSNMPSwitch
ZTEMemory UtilizationMonitors the Memory of ZTE-2850-26TM SwitchSNMPSwitch
ZTEMemory UtilizationMonitors the Memory of ZTE-ZXPON-C220 SwitchSNMPSwitch
ZTEMemory UtilizationMonitors the Memory of ZTE-ZXR10-2826E SwitchSNMPSwitch
ZTEMemory UtilizationMonitors the Memory of ZTE-ZXR10-2826S-LE SwitchSNMPSwitch
ZTEMemory UtilizationMemory Utilization for ZTESNMPSwitch
Video Zone
OpManager Customer Videos
Michael Senatore, Operations Manager, Rojan Australia Pty Ltd.
  
  •  Venkatesan Veerappan, IT Consultant
     Mohd Jaffer Tawfiq Murtaja, Information Security officer from Al Ain sports club
  •  Jonathan ManageEngine Customer
     IT Admin from "Royal flying doctor service", Australia
  •  Michael Senatore, Operations Manager, Rojan Australia Pty Ltd.
     Michael - Network & Tech, ManageEngine Customer
  •  Altaleb Alshenqiti - Ministry of National Guard - Health Affairs
     Donald Stewart, IT Manager from Crest Industries
  •  John Rosser, MIS Manager - Yale Chase Equipment & Services
     David Tremont, Associate Directory of Infrastructure,USA