Installing OpManager MSP in AWS helps in ensuring world class network management for your device while eliminating the need for a physical server for monitoring.
You can use OpManager MSP in AWS using either one of the 2 methods.
Purchase OpManager MSP AMI from here.
Before installing OpManager MSP at AWS, ensure that you meet the following pre-requisites
|
Port |
Protocol |
Port Type |
Usage |
Remarks |
|
13306 |
TCP |
Static (PostgreSQL) |
Database Port |
Can be changed in conf/database_params.conf file. |
|
1433 |
TCP |
Static (MS SQL) |
Database Port |
Can be changed in conf/database_params.conf file/ dbconfiguration.bat file. |
|
22 |
TCP |
Static |
SSH Port |
|
|
8060 |
TCP |
Static |
Web Server Port |
Can be configured using ChangeWebServerPort.bat. |
|
161 |
UDP |
Static |
SNMP |
|
|
135 |
TCP |
Static |
WMI |
|
|
445 |
TCP |
Static |
WMI |
|
|
5000 to 6000 |
TCP |
Dynamic |
WMI |
|
|
49152 to 65535 |
TCP |
Dynamic |
WMI |
Windows 2008R2 and higher |
|
2000 |
TCP |
Static |
Internal Communication Port |
|
|
56328 |
TCP |
Dynamic |
ShutDown Listener Port |
|
|
162 |
UDP |
Static |
SNMP Trap Receiver Port |
|
|
514 |
UDP |
Static |
SYSLOG Receiver Port |
SYSLOG Receiver Port can be changed via WebClient |
|
69 |
UDP |
Static |
TFTP Port [NCM] |
|
|
1514 |
UDP |
Static |
Firewall Log Receiver [FWA] |
Firewall Receiver Port can be changed via WebClient |
|
9996 |
TCP |
NetFlow Listener Port [NFA] |
NetFlow Listener Port can be changed via WebClient |