Integrate OpManager with Anthropic

Connect OpManager to Anthropic's Claude models to generate alarm, device, device group, and problem summaries, scripts, and SNMP OID suggestions. You need a Claude Console account and an API key.

Privacy: To safeguard sensitive data, OpManager applies a PII masking layer before any information is sent to SiliconFlow. Device and user identifiers (including IP addresses, hostnames, and serial numbers) are masked prior to transmission and automatically restored in the response, ensuring generated summaries and scripts remain accurate without exposing sensitive details to the AI vendor.

Configuring Anthropic in OpManager

AI-generated summaries and scripts require the Anthropic integration to be configured first. You will need an API key from your Anthropic account.

  1. Go to Settings → General Settings → Integrations → Anthropic.
  2. Enter your API Key.
  3. Optionally, enter an Organization Name.

Anthropic Integration - ManageEngine OpManager

  1. Click Fetch Model to retrieve the models available for your API key. Fetch Model must be completed before a model can be selected. If the API key is invalid, no models are returned.
  2. Select a model from the Model dropdown. If the model you need isn't listed, select Custom and enter its model name. The model must be a Claude text-generation model.
  3. Select a Token Count: 1000, 2000, or 3000. To use a different value, select Custom and enter a number between 250 and 8000. Use the following guidance:
    • What it controls: Token Count sets the ceiling on the number of tokens the model can use to generate a response. A higher value helps accommodate more detailed summaries and scripts, if the model generates them.
    • Recommended range: 1,000 to 2,000 tokens for Device Summary, Device Group Summary, All Alarms Summary, and SNMP OID generation; 2,000 to 3,000 tokens for Individual Alarm Summary, Problem Summary, and Script Generation. Do not exceed the maximum output limit of the selected model.
      • Treat these values as a starting point rather than a fixed rule. The tokens needed depend on the model and how much reasoning it applies. One model may produce a summary in under 1,000 tokens, while a more reasoning-heavy model may need 4,000 to 5,000 tokens for a basic device summary. In general, the ranges above work well.
    • Trade-offs: Higher values increase Anthropic usage cost and response time. Values that are too low can truncate the response, especially for features that use more tokens, such as Problem Summary and Script Generation.
  4. Acknowledge the data privacy notice and click Proceed.

Anthropic Integration Data Privacy Notice - ManageEngine OpManager

  1. Click Save.

To verify the integration, enable Anthropic for All Alarms Summary on the AI Settings page, go to Alarms, and click the Summarize tab. The summary should carry the Generated by Anthropic tag.

AI Settings

Once Anthropic is configured, use the AI Settings page to choose which features use Anthropic and which model handles each one. Go to Settings → General Settings → AI Settings.

To use Anthropic for every feature, enable the Apply to all features checkbox. Otherwise, enable each feature individually and select Anthropic as its vendor, along with a model. For example, alarm summaries can use Anthropic while script generation uses another vendor.

After saving, generated summaries and scripts carry a Generated by Anthropic tag, so you can confirm which vendor produced the content.

For the full list of AI features and PII masking details, see AI Settings.

AI Features in OpManager

With Anthropic enabled for a feature on the AI Settings page, the following capabilities are available:

All Alarms Summary

Consolidates all active alarms into a single summary highlighting the most critical details.

  1. Go to Alarms and click the Summarize tab at the top-right.
  2. The summary is generated automatically.

All Alarms Summary by Anthropic Integration - ManageEngine OpManager

Individual Alarm Summary

Identifies the alarm type, lists probable causes, and suggests recommended steps for a single alarm.

  1. Go to Alarms and open any alarm.
  2. Click the Summarize tab to generate the summary.

Individual Alarm Summary by Anthropic Integration - ManageEngine OpManager

Device Group Summary

Provides a consolidated view of device conditions, key metrics, and recommendations across all devices in a group.

  1. Go to Settings → Configurations → Groups. You can also open Groups from the Inventory.
  2. Select a device group and click the Summarize tab.

Device Group Summary by Anthropic Integration - ManageEngine OpManager

Device Summary

Summarizes the health and key metrics of an individual device.

  1. Go to Inventory and select a device to open its snapshot page.
  2. Click the Summarize tab.

Device Summary by Anthropic Integration - ManageEngine OpManager

Problem Summary

Works with Event Correlation, which groups related alarms into a single Problem. Anthropic analyzes the associated alarms and identifies the probable cause with a high or medium confidence level, along with suggested next steps.

  1. Go to Alarms → Problems and open a Problem.
  2. Click Analyze with AI.

Problem Summary by Anthropic Integration - ManageEngine OpManager

Script Generation

Generates monitoring scripts for script templates from a plain-language prompt.

  1. Ensure Script Generation is enabled on the AI Settings page.
  2. Go to Settings → Monitoring → Script Templates.
  3. Click Add and enter the monitoring details.
  4. Under Script Details, click Generate with AI.

Script Template page with Generate with AI - ManageEngine OpManager

  1. Enter a description of the script you need (for example: PowerShell script that returns free space percentage on C: as a number).
  2. Click Generate. Review the script and save it as a template for monitoring.

Script Generation by Anthropic Integration - ManageEngine OpManager

Caution: AI-generated scripts can contain errors or unintended commands. Always review the generated script, and test it on a non-production device, before saving it as a template and deploying it for monitoring.

SNMP OIDs for Performance Monitors

Fetches the OID, MIB name, and a short description for a metric you describe in plain language.

Note: Fetching SNMP OIDs for Performance Monitors is available from OpManager version 12.9.120 onward.

  1. Ensure SNMP OIDs for Performance Monitors is enabled on the AI Settings page.
  2. Go to Actions → Add SNMP Monitor and select the target device.
  3. Click Get OID Details.
  4. Describe the metric to monitor, including the device type or model if known, and click Fetch.
  5. Click Use this OID to populate the formula field.
  6. Click the Query Device icon to verify the OID, then save the monitor.

SNMP OID lookup by Anthropic Integration - ManageEngine OpManager

The OpManager—Anthropic integration brings Claude-powered alarm, device, device group, and problem summaries, script generation, and SNMP OID lookup into a single workflow, reducing manual analysis and helping teams act on network issues faster.